الوصف: In 2003 the M501G at Mitsubishi's in-house combined cycle power plant facility located at Takasago (T-Point) was upgraded. The upgrade was accomplished by replacing some of the existing hardware in the M501G gas turbine, for further improvements in output and heat rate. The verification testing at this power plant has been continuing with MHI's latest upgraded combustor technology, that has successfully demonstrated NOx levels at 15ppm and 9ppm or lower emission levels in Mitsubishi's G and F gas turbines, respectively. The upgraded M501G has been officially designated as the M501G1 gas turbine. This paper describes the upgraded hardware and the operating experience at the T-Point power plant.