Conference
Wearable impedance monitoring system for dialysis patients
العنوان: | Wearable impedance monitoring system for dialysis patients |
---|---|
المؤلفون: | Bonnet, Stephane, Bourgerette, A., Gharbi, S., Rubeck, C., Arkouche, W., Massot, B., Mcadams, Eric, Montalibet, A., Jallon, P. |
المساهمون: | Commissariat à l'énergie atomique et aux énergies alternatives - Laboratoire d'Electronique et de Technologie de l'Information (CEA-LETI), Direction de Recherche Technologique (CEA) (DRT (CEA)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA), Association pour l'Utilisation du Rein Artificiel Région Lyonnaise (AURAL), INL - Capteurs Biomédicaux (INL - Capteurs), Institut des Nanotechnologies de Lyon (INL), École Centrale de Lyon (ECL), Université de Lyon-Université de Lyon-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-École Supérieure de Chimie Physique Électronique de Lyon (CPE)-Institut National des Sciences Appliquées de Lyon (INSA Lyon), Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Centre National de la Recherche Scientifique (CNRS)-École Centrale de Lyon (ECL), Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Centre National de la Recherche Scientifique (CNRS) |
المصدر: | 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) https://hal.science/hal-01985483 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Aug 2016, Orlando, United States. ⟨10.1109/EMBC.2016.7591898⟩ |
بيانات النشر: | HAL CCSD |
سنة النشر: | 2016 |
المجموعة: | Université de Lyon: HAL |
مصطلحات موضوعية: | [SPI]Engineering Sciences [physics] |
جغرافية الموضوع: | Orlando, United States |
الوصف: | International audience ; This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis. |
نوع الوثيقة: | conference object |
اللغة: | English |
Relation: | hal-01985483; https://hal.science/hal-01985483; https://hal.science/hal-01985483/document; https://hal.science/hal-01985483/file/BonnetMontalibet2016.pdf |
DOI: | 10.1109/EMBC.2016.7591898 |
الاتاحة: | https://hal.science/hal-01985483 https://hal.science/hal-01985483/document https://hal.science/hal-01985483/file/BonnetMontalibet2016.pdf https://doi.org/10.1109/EMBC.2016.7591898 |
Rights: | info:eu-repo/semantics/OpenAccess |
رقم الانضمام: | edsbas.7950206E |
قاعدة البيانات: | BASE |
DOI: | 10.1109/EMBC.2016.7591898 |
---|