Academic Journal
FUNCTIONAL STUDIES ON BLOOD MICROCIRCULATION SYSTEM WITH LASER DOPPLER FLOWMETRY IN CLINICAL MEDICINE: PROBLEMS AND PROSPECTS ; ФУНКЦИОНАЛЬНЫЕ ИССЛЕДОВАНИЯ СИСТЕМЫ МИКРОЦИРКУЛЯЦИИ КРОВИ МЕТОДОМ ЛАЗЕРНОЙ ДОПЛЕРОВСКОЙ ФЛОУМЕТРИИ В КЛИНИЧЕСКОЙ МЕДИЦИНЕ: ПРОБЛЕМЫ И ПЕРСПЕКТИВЫ
العنوان: | FUNCTIONAL STUDIES ON BLOOD MICROCIRCULATION SYSTEM WITH LASER DOPPLER FLOWMETRY IN CLINICAL MEDICINE: PROBLEMS AND PROSPECTS ; ФУНКЦИОНАЛЬНЫЕ ИССЛЕДОВАНИЯ СИСТЕМЫ МИКРОЦИРКУЛЯЦИИ КРОВИ МЕТОДОМ ЛАЗЕРНОЙ ДОПЛЕРОВСКОЙ ФЛОУМЕТРИИ В КЛИНИЧЕСКОЙ МЕДИЦИНЕ: ПРОБЛЕМЫ И ПЕРСПЕКТИВЫ |
---|---|
المؤلفون: | Lapitan D.G., Rogatkin D.A. |
المصدر: | Almanac of Clinical Medicine; Vol 44, No 2 (2016); 249-259 ; Альманах клинической медицины; Vol 44, No 2 (2016); 249-259 ; 2587-9294 ; 2072-0505 ; 10.18786/2072-0505-2016-44-2 |
بيانات النشر: | Moscow Region Research and Clinical Institute (MONIKI) |
سنة النشر: | 2016 |
المجموعة: | Almanac of Clinical Medicine (E-Journal) / Альманах клинической медицины |
مصطلحات موضوعية: | blood microcirculation system, laser Doppler flowmetry, functional tests, index of blood microcirculation, blood perfusion, variability, система микроциркуляции крови, лазерная доплеровская флоуметрия, функциональные пробы, показатель микроциркуляции, перфузия крови, вариабельность |
الوصف: | The paper presents a review of the research update on the blood microcirculation system assessed with laser Doppler flowmetry (LDF). Specific procedures for measurement of the microcirculation index by LDF and individual variability of microcirculation parameters during their real time assessment in vivo are discussed. In physiological conditions, a relative deviation of the results of measurements by LDF is within the range±35% and above from the mean value of the microcirculation index. This imposes certain limitations on the interpretation of the diagnostic results in terms of the “normal or pathologic”. Specifics of performance of functional stress tests on the microcirculation system are reviewed. Diagnostic criteria based on functional stress testing of the microcirculation system, which can be implemented with methodologically strict normatives and regulations, for examples, those for the occlusion test, are more reliable from metrologic perspective and significant compared to the results obtained without stress testing. Problems of implementation of the functional tests into clinical practice are discussed. It was shown that they may have a potentially wide spectrum of clinical indications, from functional diagnostics and early detection of microcirculatory abnormalities in diabetes mellitus, arterial hypertension and other diseases associated with microcirculatory disorders, to the physical rationale of exposure parameters, as well as objectification of efficiency of medical procedures aimed to stimulation of the microcirculatory functions in a patient's tissues and organs. ; В статье представлен обзор современных данных по исследованию системы микроциркуляции крови методом лазерной доплеровской флоуметрии (ЛДФ). Рассмотрены особенности оценки показателя микроциркуляции методом ЛДФ, обсуждается индивидуальная вариабельность параметров микроциркуляции, измеряемых в реальном масштабе времени in vivo. Относительный физиологический разброс результатов измерений в ЛДФ находится в диапазоне не менее ±35% от ... |
نوع الوثيقة: | article in journal/newspaper |
وصف الملف: | application/pdf |
اللغة: | Russian |
Relation: | https://almclinmed.ru/jour/article/view/344/350; https://almclinmed.ru/jour/article/view/344 |
DOI: | 10.18786/2072-0505-2016-44-2-249-259 |
الاتاحة: | https://almclinmed.ru/jour/article/view/344 https://doi.org/10.18786/2072-0505-2016-44-2-249-259 |
Rights: | Copyright (c) 2016 Lapitan D.G., Rogatkin D.A. ; https://creativecommons.org/licenses/by/4.0 |
رقم الانضمام: | edsbas.734E6CFF |
قاعدة البيانات: | BASE |
DOI: | 10.18786/2072-0505-2016-44-2-249-259 |
---|