Academic Journal

Rapid analysis of six phthalate esters in wine by ultrasound-vortex-assisted dispersive liquid-liquid micro-extraction coupled with gas chromatography-flame ionization detector or gas chromatography-ion trap mass spectrometry

التفاصيل البيبلوغرافية
العنوان: Rapid analysis of six phthalate esters in wine by ultrasound-vortex-assisted dispersive liquid-liquid micro-extraction coupled with gas chromatography-flame ionization detector or gas chromatography-ion trap mass spectrometry
المؤلفون: G. Cinelli, NOTARDONATO, Ivan, A. Centola, RUSSO, Mario Vincenzo, AVINO P
المساهمون: G., Cinelli, Notardonato, Ivan, A., Centola, Russo, Mario Vincenzo, Avino, P
سنة النشر: 2013
المجموعة: Università degli Studi del Molise: IRIS
الوصف: "An Ultrasound-Vortex-Assisted Dispersive Liquid-Liquid Micro-Extraction (USVADLLME) procedure coupled with Gas Chromatography-Flame Ionization Detector (GC-FID) or Gas Chromatography-Ion Trap Mass Spectrometry (GC-IT\/MS) is proposed for rapid analysis of six phthalate esters in hydroalcoholic beverages (alcohol by volume, alc vol−1, ≤ 40%). Under optimal conditions, the enrichment factor of the six analytes ranges from 220 to 300 fold and the recovery from 85% to 100.5%. The limit of detection (LOD) and limit of quantification (LOQ) are ≥ 0.022 μg L−1 and ≥ 0.075 μg L−1, respectively. Intra-day and inter-day precisions expressed as relative standard deviation (RSD), are ≤ 8.2% and ≤ 7.0%, respectively. The whole proposed methodology has demonstrated to be simple, reproducible and sensible for the determination of trace phthalate esters in red and white wine samples" ; An Ultrasound-Vortex-Assisted Dispersive Liquid-Liquid Micro-Extraction (USVADLLME) procedure coupled with Gas Chromatography-Flame Ionization Detector (GC-FID) or Gas Chromatography-Ion Trap Mass Spectrometry (GC-IT/MS) is proposed for rapid analysis of six phthalate esters in hydroalcoholic beverages (alcohol by volume, alcvol-1, ≤40%). Under optimal conditions, the enrichment factor of the six analytes ranges from 220- to 300-fold and the recovery from 85% to 100.5%. The limit of detection (LOD) and limit of quantification (LOQ) are ≥0.022μgL-1 and ≥0.075μgL-1, respectively. Intra-day and inter-day precisions expressed as relative standard deviation (RSD), are ≤8.2% and ≤7.0%, respectively. The whole proposed methodology has demonstrated to be simple, reproducible and sensible for the determination of trace phthalate esters in red and white wine samples.
نوع الوثيقة: article in journal/newspaper
اللغة: English
Relation: info:eu-repo/semantics/altIdentifier/pmid/23498123; info:eu-repo/semantics/altIdentifier/wos/WOS:000316591400009; volume:769; firstpage:72; lastpage:78; numberofpages:7; journal:ANALYTICA CHIMICA ACTA; http://hdl.handle.net/11695/45824; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84875000307
DOI: 10.1016/j.aca.2013.01.031
الاتاحة: http://hdl.handle.net/11695/45824
https://doi.org/10.1016/j.aca.2013.01.031
رقم الانضمام: edsbas.6D2E9BA
قاعدة البيانات: BASE
الوصف
DOI:10.1016/j.aca.2013.01.031