Academic Journal
Residual motion of different posterior instrumentation and interbody fusion constructs
العنوان: | Residual motion of different posterior instrumentation and interbody fusion constructs |
---|---|
المؤلفون: | Burkhard, Marco D, Spirig, José M, Wanivenhaus, Florian, Cornaz, Frédéric, Fasser, Marie-Rosa, Widmer, Jonas, Farshad, Mazda |
المصدر: | Burkhard, Marco D; Spirig, José M; Wanivenhaus, Florian; Cornaz, Frédéric; Fasser, Marie-Rosa; Widmer, Jonas; Farshad, Mazda (2023). Residual motion of different posterior instrumentation and interbody fusion constructs. European Spine Journal, 32(4):1411-1420. |
بيانات النشر: | Springer |
سنة النشر: | 2023 |
المجموعة: | University of Zurich (UZH): ZORA (Zurich Open Repository and Archive |
مصطلحات موضوعية: | Balgrist University Hospital, Swiss Spinal Cord Injury Center, 610 Medicine & health, Facet-sparing, Interbody fusion, PLIF, TLIF, Unilateral |
الوصف: | PURPOSE: To elucidate residual motion of cortical screw (CS) and pedicle screw (PS) constructs with unilateral posterior lumbar interbody fusion (ul-PLIF), bilateral PLIF (bl-PLIF), facet-sparing transforaminal lumbar interbody fusion (fs-TLIF), and facet-resecting TLIF (fr-TLIF). METHODS: A total of 35 human cadaver lumbar segments were instrumented with PS (n = 18) and CS (n = 17). Range of motion (ROM) and relative ROM changes were recorded in flexion/extension (FE), lateral bending (LB), axial rotation (AR), lateral shear (LS), anterior shear (AS), and axial compression (AC) in five instrumentational states: without interbody fusion (wo-IF), ul-PLIF, bl-PLIF, fs-TLIF, and fr-TLIF. RESULTS: Whereas FE, LB, AR, and AC noticeably differed between the instrumentational states, AS and LS were less prominently affected. Compared to wo-IF, ul-PLIF caused a significant increase in ROM with PS (FE + 42%, LB + 24%, AR + 34%, and AC + 77%), however, such changes were non-significant with CS. ROM was similar between wo-IF and all other interbody fusion techniques. Insertion of a second PLIF (bl-PLIF) significantly decreased ROM with CS (FE -17%, LB -26%, AR -20%, AC -51%) and PS (FE - 23%, LB - 14%, AR - 20%, AC - 45%,). Facet removal in TLIF significantly increased ROM with CS (FE + 6%, LB + 9%, AR + 17%, AC of + 23%) and PS (FE + 7%, AR + 12%, AC + 13%). CONCLUSION: bl-PLIF and TLIF show similarly low residual motion in both PS and CS constructs, but ul-PLIF results in increased motion. The fs-TLIF technique is able to further decrease motion compared to fr-TLIF in both the CS and PS constructs. |
نوع الوثيقة: | article in journal/newspaper |
وصف الملف: | application/pdf |
اللغة: | English |
تدمد: | 0940-6719 |
Relation: | https://www.zora.uzh.ch/id/eprint/254368/1/2023_Burkhard_Residual_motion_of_different_posterior_instrumentation_and_interbody_fusion_constructs_ESJ.pdf; info:pmid/36820922; urn:issn:0940-6719 |
الاتاحة: | https://www.zora.uzh.ch/id/eprint/254368/ https://www.zora.uzh.ch/id/eprint/254368/1/2023_Burkhard_Residual_motion_of_different_posterior_instrumentation_and_interbody_fusion_constructs_ESJ.pdf |
Rights: | info:eu-repo/semantics/openAccess ; Creative Commons: Attribution 4.0 International (CC BY 4.0) ; http://creativecommons.org/licenses/by/4.0/ |
رقم الانضمام: | edsbas.61084F70 |
قاعدة البيانات: | BASE |
تدمد: | 09406719 |
---|