Table_2_Stereotactic and Robotic Minimally Invasive Thermal Ablation of Malignant Liver Tumors: A Systematic Review and Meta-Analysis.xlsx

التفاصيل البيبلوغرافية
العنوان: Table_2_Stereotactic and Robotic Minimally Invasive Thermal Ablation of Malignant Liver Tumors: A Systematic Review and Meta-Analysis.xlsx
المؤلفون: Pascale Tinguely (5264273), Iwan Paolucci (10279514), Simeon J. S. Ruiter (10279517), Stefan Weber (44254), Koert P. de Jong (8533890), Daniel Candinas (174264), Jacob Freedman (4766781), Jennie Engstrand (4766778)
سنة النشر: 2021
المجموعة: Smithsonian Institution: Digital Repository
مصطلحات موضوعية: Cancer, Cancer Cell Biology, Cancer Diagnosis, Cancer Genetics, Cancer Therapy (excl. Chemotherapy and Radiation Therapy), Chemotherapy, Haematological Tumours, Molecular Targets, Radiation Therapy, Solid Tumours, Oncology and Carcinogenesis not elsewhere classified, liver neoplasms, ablation techniques, stereotaxic techniques, computer-assisted therapies, minimally invasive surgical procedures
الوصف: Background Stereotactic navigation techniques aim to enhance treatment precision and safety in minimally invasive thermal ablation of liver tumors. We qualitatively reviewed and quantitatively summarized the available literature on procedural and clinical outcomes after stereotactic navigated ablation of malignant liver tumors. Methods A systematic literature search was performed on procedural and clinical outcomes when using stereotactic or robotic navigation for laparoscopic or percutaneous thermal ablation. The online databases Medline, Embase, and Cochrane Library were searched. Endpoints included targeting accuracy, procedural efficiency, and treatment efficacy outcomes. Meta-analysis including subgroup analyses was performed. Results Thirty-four studies (two randomized controlled trials, three prospective cohort studies, 29 case series) were qualitatively analyzed, and 22 studies were included for meta-analysis. Weighted average lateral targeting error was 3.7 mm (CI 3.2, 4.2), with all four comparative studies showing enhanced targeting accuracy compared to free-hand targeting. Weighted average overall complications, major complications, and mortality were 11.4% (6.7, 16.1), 3.4% (2.1, 5.1), and 0.8% (0.5, 1.3). Pooled estimates of primary technique efficacy were 94% (89, 97) if assessed at 1–6 weeks and 90% (87, 93) if assessed at 6–12 weeks post ablation, with remaining between-study heterogeneity. Primary technique efficacy was significantly enhanced in stereotactic vs. free-hand targeting, with odds ratio (OR) of 1.9 (1.2, 3.2) (n = 6 studies). Conclusions Advances in stereotactic navigation technologies allow highly precise and safe tumor targeting, leading to enhanced primary treatment efficacy. The use of varying definitions and terminology of safety and efficacy limits comparability among studies, highlighting the crucial need for further standardization of follow-up definitions.
نوع الوثيقة: dataset
اللغة: unknown
Relation: https://figshare.com/articles/dataset/Table_2_Stereotactic_and_Robotic_Minimally_Invasive_Thermal_Ablation_of_Malignant_Liver_Tumors_A_Systematic_Review_and_Meta-Analysis_xlsx/16665502
DOI: 10.3389/fonc.2021.713685.s003
الاتاحة: https://doi.org/10.3389/fonc.2021.713685.s003
Rights: CC BY 4.0
رقم الانضمام: edsbas.49C2F234
قاعدة البيانات: BASE
الوصف
DOI:10.3389/fonc.2021.713685.s003