Academic Journal

Early Outcomes of Sutureless Aortic Valves

التفاصيل البيبلوغرافية
العنوان: Early Outcomes of Sutureless Aortic Valves
المؤلفون: Muhammet Onur Hanedan, İlker Mataracı, Mehmet Ali Yürük, Tanıl Özer, Ufuk Sayar, Ali Kemal Arslan, Uğur Ziyrek, Murat Yücel
المصدر: Korean Journal of Thoracic and Cardiovascular Surgery, Vol 49, Iss 3, Pp 165-170 (2016)
بيانات النشر: Korean Society for Thoracic and Cardiovascular Surgery
سنة النشر: 2016
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: Prosthesis design, Heart valve prosthesis implantation, Bioprosthesis, Surgery, RD1-811
الوصف: Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results: The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.
نوع الوثيقة: article in journal/newspaper
اللغة: English
Korean
تدمد: 2233-601X
2093-6516
Relation: http://www.kjtcvs.org/journal/download_pdf.php?doi=10.5090/kjtcs.2016.49.3.165; https://doaj.org/toc/2233-601X; https://doaj.org/toc/2093-6516; https://doaj.org/article/14730b6a1f2c443e96ec56939240427a
DOI: 10.5090/kjtcs.2016.49.3.165
الاتاحة: https://doi.org/10.5090/kjtcs.2016.49.3.165
https://doaj.org/article/14730b6a1f2c443e96ec56939240427a
رقم الانضمام: edsbas.4435D41A
قاعدة البيانات: BASE
الوصف
تدمد:2233601X
20936516
DOI:10.5090/kjtcs.2016.49.3.165