Academic Journal

Compact Eucapnic Voluntary Hyperpnoea Apparatus for Exercise-Induced Respiratory Disease Detection

التفاصيل البيبلوغرافية
العنوان: Compact Eucapnic Voluntary Hyperpnoea Apparatus for Exercise-Induced Respiratory Disease Detection
المؤلفون: Lulu Wang, Ahmed Al-Jumaily
المصدر: Sensors; Volume 17; Issue 5; Pages: 1139
بيانات النشر: Multidisciplinary Digital Publishing Institute
سنة النشر: 2017
المجموعة: MDPI Open Access Publishing
مصطلحات موضوعية: eucapnic voluntary hyperpnoea, exercise-induced asthma, exercise-induced bronchoconstriction, bronchoprovocation technique, eucapnic voluntary hyperventilation, maximum voluntary ventilation
الوصف: Eucapnic voluntary hyperpnoea (EVH) challenge provides objective criteria for exercise-induced asthma (EIA) or exercise-induced bronchoconstriction (EIB), and it was recommended to justify the use of inhaled β2-agonists by athletes for the Olympics. This paper presents the development of a compact and easy-to-use EVH apparatus for assessing EIB in human subjects. The compact apparatus has been validated on human subjects and the results have been compared to the conventional EVH system. Twenty-two swimmers, including eleven healthy subjects and eleven subjects who had been physician-diagnosed with asthma, were recruited from sport and recreation centers throughout Auckland, New Zealand. Each subject performed two EVH challenge tests using the proposed breathing apparatus and the conventional Phillips EVH apparatus on separate days, respectively. Forced expiratory volume in one second (FEV1) was measured before and after the challenges. A reduction in FEV1 of 10% or more was considered positive. Of the eleven subjects who were previously diagnosed with asthma, EIB was present in all subjects (100%) in the compact EVH group, while it was presented in ten subjects (90.91%) in the conventional EVH challenge group. Of the eleven healthy subjects, EIB was present in one subject (4.55%) in the compact EVH group, while it was not present in the conventional EVH group. Experimental results showed that the compact EVH system has potential to become an alternative tool for EIB detection.
نوع الوثيقة: text
وصف الملف: application/pdf
اللغة: English
Relation: Physical Sensors; https://dx.doi.org/10.3390/s17051139
DOI: 10.3390/s17051139
الاتاحة: https://doi.org/10.3390/s17051139
Rights: https://creativecommons.org/licenses/by/4.0/
رقم الانضمام: edsbas.426291A9
قاعدة البيانات: BASE