Academic Journal

The Use of a CAD/CAM Thermoformed Splints System in Closed Reduction of Condylar Fractures

التفاصيل البيبلوغرافية
العنوان: The Use of a CAD/CAM Thermoformed Splints System in Closed Reduction of Condylar Fractures
المؤلفون: Cristina Grippaudo, Gianmarco Saponaro, Alessandro Moro, Antonio D’Addona
المساهمون: Grippaudo, Cristina, Antonino Lo Giudice, †, Saponaro, Gianmarco, Todaro, Mattia, Moro, Alessandro, D'Addona, Antonio
سنة النشر: 2023
المجموعة: Università Cattolica del Sacro Cuore: PubliCatt
مصطلحات موضوعية: CAD/CAM, condylar fractures, maxillo mandibular fixation, Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
الوصف: (1) Background: Mandibular fractures are very common. Common indications of closed treatment for mandibular fractures are non-displaced or minimally displaced simple fractures in adult compliant patients with good dentition, the absence of occlusal disruption, and fractures in growing children. In closed treatment, the mandible is maintained in centric occlusion with a maxil lomandibular fixation (MMF) with orthodontic elastics. Many methods of MMF have been described, often using orthodontic appliances. In recent years, CAD-CAM technology has improved many procedures used in maxillofacial surgery and orthodontics. The device we present is manufactured following a digital workflow, and was designed specifically for MMF. (2) Materials: Two patients with mandibular fractures were treated with an MMF method whose procedure comprised scanning of the dental arches, followed by construction of thermoformed splints on which buttons for the elastics and retention holes are made. The splints were fixed on the dental arches with composite resin at the level of the holes, and were kept in place for the period of healing of the fracture, with the intermaxillary elastics hooked to the buttons. (3) Results: The application time of the splints was very quick. The splints remained stable for the necessary time, without causing particular discomfort to the patients. (4) Conclusions: From our experience, this technique has proved to be reliable an
نوع الوثيقة: article in journal/newspaper
اللغة: English
Relation: info:eu-repo/semantics/altIdentifier/wos/WOS:001073393000001; volume:2023; issue:10; firstpage:1; lastpage:12; numberofpages:12; issueyear:2023; journal:BIOENGINEERING; https://hdl.handle.net/10807/247574; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85172179288
DOI: 10.3390/bioengineering10091023
الاتاحة: https://hdl.handle.net/10807/247574
https://doi.org/10.3390/bioengineering10091023
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.1D2A6526
قاعدة البيانات: BASE
الوصف
DOI:10.3390/bioengineering10091023