Randomized evaluation of the performance of single-use laryngoscopes in simulated easy and dif®cult intubation
العنوان: | Randomized evaluation of the performance of single-use laryngoscopes in simulated easy and dif®cult intubation |
---|---|
المؤلفون: | S. J. Twigg, B. Mccormick, T. M. Cook |
المساهمون: | The Pennsylvania State University CiteSeerX Archives |
المصدر: | http://bja.oxfordjournals.org/content/90/1/8.full.pdf. |
سنة النشر: | 2002 |
المجموعة: | CiteSeerX |
مصطلحات موضوعية: | complications, prion diseases, Creutzfeldt±Jakob disease, equipment, disposable |
الوصف: | Background. Single-use laryngoscopes are becoming used more widely. Methods. We compared six types of single-use laryngoscope with the standard Macintosh laryngoscope using the Laerdal SimManÔ patient simulator. Twenty anaesthetists attempted to intubate the simulator with standardized airway settings allowing a full view of the vocal cords (`easy intubation'). The airway settings were then changed so that only the posterior part of the glottis was visible (`dif®cult intubation') and the anaesthetists were asked to intubate the simulator again. Results. The time to intubate with the standard laryngoscope was less in both easy (P<0.05) and dif®cult (P<0.01) intubations. The performance of ®ve laryngoscopes during easy intubation (P<0.01) and four during dif®cult intubation (P<0.001) was signi®cantly worse than that of the Macintosh. There was a signi®cant difference in Cormack and Lehane grading between the laryngoscopes tested in both easy (P<0.05) and dif®cult (P<0.05) intubation. The percentage of glottic opening visible (POGO score) also differed between laryngoscopes in both the easy (P<0.01) and dif®cult (P<0.001) groups. The highest POGO scores were obtained with the Macintosh laryngoscope. During the dif®cult intubation simulation, the reusable Macintosh laryngoscope needed less use of a bougie and had fewer failed intubations than the single-use laryngoscopes, but these differences did not reach statistical signi®cance. Conclusions. Of the laryngoscopes tested, the standard reusable Macintosh laryngoscope performed best. The EuropaÔ was the best single-use laryngoscope. Some single-use laryngo-scopes tested were signi®cantly inferior to the Macintosh. This raises concern over their use in clinical practice, particularly if intubation is dif®cult. |
نوع الوثيقة: | text |
وصف الملف: | application/pdf |
اللغة: | English |
Relation: | http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.554.5159; http://bja.oxfordjournals.org/content/90/1/8.full.pdf |
الاتاحة: | http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.554.5159 http://bja.oxfordjournals.org/content/90/1/8.full.pdf |
Rights: | Metadata may be used without restrictions as long as the oai identifier remains attached to it. |
رقم الانضمام: | edsbas.1CBA5DD7 |
قاعدة البيانات: | BASE |
الوصف غير متاح. |