Quantitative strain elastography of the uterine cervix assessed by the GE Voluson E10 system in combination with a force-measuring device

التفاصيل البيبلوغرافية
العنوان: Quantitative strain elastography of the uterine cervix assessed by the GE Voluson E10 system in combination with a force-measuring device
المؤلفون: Rohr Thomsen, Christine, Leonhard, Anne Katrine, Strandbo Schmidt Jensen, Maria, Bor, Pinar, Hinge, Mogens, Uldbjerg, Niels, Sandager, Puk
المصدر: Rohr Thomsen , C , Leonhard , A K , Strandbo Schmidt Jensen , M , Bor , P , Hinge , M , Uldbjerg , N & Sandager , P 2023 , ' Quantitative strain elastography of the uterine cervix assessed by the GE Voluson E10 system in combination with a force-measuring device ' , Journal of Maternal-Fetal and Neonatal Medicine , vol. 36 , no. 1 , 2213797 . https://doi.org/10.1080/14767058.2023.2213797
سنة النشر: 2023
المجموعة: Aarhus University: Research
مصطلحات موضوعية: force-measuring device, gestational age, labor induction, strain elastography, Uterine cervix
الوصف: Objective: During pregnancy, the stiffness of the cervical tissue decreases long before the cervical length decreases. Therefore, several approaches have been proposed in order to ensure a more objective assessment of cervical stiffness than that achieved by digital evaluation. Strain elastography has shown promising results. This technique is based on an ultrasound assessment of the tissue deformation that occurs when the examiner applies pressure on the tissue with the ultrasound probe. However, the results are only semi-quantitative as they depend on the unmeasured force used by the examiner. We, therefore, hypothesized that a force-measuring device applied to the handle of the ultrasound probe may render the technique quantitative. With this approach, the stiffness is the force (measured by the device) divided by the compression (measured by the elastography platform). One perspective is the early identification of women at risk of preterm birth in whom cervical stiffness may decrease long before cervical shortening. Another perspective is cervical evaluation when planning labor induction. In this feasibility study, we aimed to evaluate how quantitative strain elastography performs when a commercially available strain elastography platform (by which the algorithm is unavailable) is combined with a custom-made, force-measuring device. We studied how the assessments were associated with the gestational age in women with uncomplicated pregnancies and how they were associated with cervical dilatation time from 4 to 10 cm in women undergoing labor induction. Methods: In the analysis, we included quantitative strain elastography assessments from 47 women with uncomplicated singleton pregnancies, with gestational age between 12 +0 and 40 +0 , and from 27 singleton term-pregnant women undergoing labor induction. The force-measuring device was mounted on the handle of a transvaginal probe. The strain values (i.e. the compression of the cervical tissue) were obtained by the elastography software of the ultrasound ...
نوع الوثيقة: article in journal/newspaper
اللغة: English
Relation: https://pure.au.dk/portal/en/publications/1a71a099-ba18-4abd-9f42-2849c24165a8
DOI: 10.1080/14767058.2023.2213797
الاتاحة: https://pure.au.dk/portal/en/publications/1a71a099-ba18-4abd-9f42-2849c24165a8
https://doi.org/10.1080/14767058.2023.2213797
http://www.scopus.com/inward/record.url?scp=85159772190&partnerID=8YFLogxK
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.1BF068D7
قاعدة البيانات: BASE
الوصف
DOI:10.1080/14767058.2023.2213797