Academic Journal

Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography-Based Clinical Target Volume Delineation Guideline for Postprostatectomy Salvage Radiation Therapy:the PERYTON-Guideline

التفاصيل البيبلوغرافية
العنوان: Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography-Based Clinical Target Volume Delineation Guideline for Postprostatectomy Salvage Radiation Therapy:the PERYTON-Guideline
المؤلفون: Staal, F H E, Janssen, J, Oprea-Lager, D E, Engelen, A M, van Limbergen, E J, Smeenk, R J, de Jong, M A A, Budiharto, T C G, Jacobs, I, Haverkort, M A D, Brouwer, C L, Siang, K Ng Wei, Langendijk, J A, Verzijlbergen, J F, de Jong, I J, Noordzij, W, Aluwini, S
المصدر: Staal , F H E , Janssen , J , Oprea-Lager , D E , Engelen , A M , van Limbergen , E J , Smeenk , R J , de Jong , M A A , Budiharto , T C G , Jacobs , I , Haverkort , M A D , Brouwer , C L , Siang , K N W , Langendijk , J A , Verzijlbergen , J F , de Jong , I J , Noordzij , W & Aluwini , S 2024 , ' Prostate-Specific Membrane Antigen Positron Emission Tomography/Computed Tomography-Based Clinical ....
سنة النشر: 2024
المجموعة: University of Groningen research database
الوصف: PURPOSE: PSMA PET/CT scan is the standard imaging procedure for biochemical recurrent prostate cancer post-prostatectomy due to its high detection rate at low serum PSA levels. However, existing guidelines for clinical target volume (CTV) in prostate bed salvage external beam radiation therapy (sEBRT) are primarily based on experience-based clinical consensus and have been validated using conventional imaging modalities. Therefore, this study aimed to optimize CTV definition in sEBRT by utilizing PSMA PET/CT-detected local recurrences (LRs). METHODS AND MATERIALS: Patients with suspected LR on PSMA PET/CT post-prostatectomy were retrospectively enrolled in nine Dutch centers. Anonymized scans were centrally reviewed by an expert nuclear medicine physician. Each boundary of the CTV guideline from the Groupe Francophone de Radiothérapie en Urologie (GFRU) was evaluated and adapted to improve the accuracy and coverage of the area at risk of LR (CTV) on PSMA PET/CT. The proposed CTV adaptation was discussed with the radiation oncologists of the participating centers, and final consensus was reached. To assess reproducibility, the participating centers were asked to delineate three new cases according to the new PERYTON-CTV, and the submitted contours were evaluated using the dice similarity coefficient (DSC). RESULTS: After central review, 93 LRs were identified on 83 PSMA PET/CTs. The proposed CTV definition improved the coverage of PSMA PET/CT-detected LRs from 67% to 96% compared to the GFRU-CTV, while reducing the GFRU-CTV volume with 25%. The new CTV was highly reproducible with a mean DSC of 0.82 (range: 0.81 to 0.83). CONCLUSIONS: This study contributes to the optimization of CTV definition in post-prostatectomy sEBRT by using the pattern of LR detected on PSMA PET/CT. The PERYTON-CTV is highly reproducible across the participating centers and ensures coverage of 96% LRs while reducing the GFRU-CTV volume with 25%.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: English
DOI: 10.1016/j.ijrobp.2023.09.016
الاتاحة: https://hdl.handle.net/11370/9a66ab3f-6f34-47e5-ad64-4da2ec1eb03c
https://research.rug.nl/en/publications/9a66ab3f-6f34-47e5-ad64-4da2ec1eb03c
https://doi.org/10.1016/j.ijrobp.2023.09.016
https://pure.rug.nl/ws/files/1086544562/1-s2.0-S0360301623079282-main.pdf
Rights: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.1B3DF022
قاعدة البيانات: BASE
الوصف
DOI:10.1016/j.ijrobp.2023.09.016