Academic Journal

Temporary implants and particulate dentin graft protecting traditional implants in severe periodontal patient: A case report

التفاصيل البيبلوغرافية
العنوان: Temporary implants and particulate dentin graft protecting traditional implants in severe periodontal patient: A case report
المؤلفون: José Luis Calvo-Guirado
المصدر: Indian Journal of Dental Sciences, Vol 13, Iss 3, Pp 201-204 (2021)
بيانات النشر: Wolters Kluwer Medknow Publications
سنة النشر: 2021
المجموعة: Directory of Open Access Journals: DOAJ Articles
مصطلحات موضوعية: dentin grafts, particulate dentin graft, particulate tooth graft, temporary implants, tr implants, transitional implants, Dentistry, RK1-715
الوصف: Provisional implants (PIs) can offer a total contribution to a patient's esthetic comfort and chew during the integration of standard implants. Although temporary implants are not intended for osseointegration and have to withdraw at there or 4 months, most of them begin to move during this process, and most of them had extracted before standard implants integration. Resin fixed prosthesis attached to temporary implant abutments gives the patient stability, gives esthetics, and gives protection to traditional implants, compared to removable prostheses, which more quickly leads to the loosening and loss of these temporary implants. Temporary implants could be used with cemented or screwed resin prosthesis or with titanium framework, depending on the patient's bite, bruxism, or clenching. All PIs are made in one piece, titanium grade 5, with V threads and a Bioetched surface (rough surface) to increase the insertion torque and bone to implant contact in soft and hard bone. Temporary upper fixed denture, relined with resin, is the easiest solution for protecting and reducing the risk of failure of some of the standard implants. The possible solution in such cases is the use of temporary implants as support for the fixed structure, acting as protection of traditional implants and bone grafts. Our clinical case was made with six temporary implants TR® 2.7 mm diameter by 13 mm length, grinding extracted teeth using smart dentin grinder, and fixed temporary denture for 3 months. At 4 months, a complete zirconium denture was screwed in standard implants.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 0976-4003
2231-2293
Relation: http://www.ijds.in/article.asp?issn=0976-4003;year=2021;volume=13;issue=3;spage=201;epage=204;aulast=Calvo-Guirado; https://doaj.org/toc/0976-4003; https://doaj.org/toc/2231-2293; https://doaj.org/article/1a6f5c99a5004b1ab710f9afb7a4699e
DOI: 10.4103/ijds.ijds_21_21
الاتاحة: https://doi.org/10.4103/ijds.ijds_21_21
https://doaj.org/article/1a6f5c99a5004b1ab710f9afb7a4699e
رقم الانضمام: edsbas.1005A5D3
قاعدة البيانات: BASE
الوصف
تدمد:09764003
22312293
DOI:10.4103/ijds.ijds_21_21