High-power test results of a 3 GHz single-cell cavity

التفاصيل البيبلوغرافية
العنوان: High-power test results of a 3 GHz single-cell cavity
المؤلفون: Amaldi, U., Bergesio, D., Bonomi, R., Degiovanni, A., Garlasché, M., Magagnin, P., Verdú-Andrés, S., Wegner, R.
سنة النشر: 2012
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Accelerator Physics, Physics - Medical Physics
الوصف: Compact, reliable and little consuming accelerators are required for the treatment of tumours with ions. TERA proposes the "cyclinac", composed of a high-frequency, fast-cycling linac which boosts the energy of the particles previously accelerated in a cyclotron. The dimensions of the linac can be reduced if high gradients are used. TERA initiated a high-gradient test program to understand the operational limit of such structures. The program foresees the design, prototyping and high-power test of several high-gradient structures operating at 3 and 5.7 GHz. The high-power tests of the 3 GHz single-cell cavity were completed in Winter 2012. The maximum BDR threshold measured for Emax of 170 MV/m and RF pulses of 2.5 \mu s was 3 x 10-6 bpp/m.
نوع الوثيقة: Working Paper
URL الوصول: http://arxiv.org/abs/1206.1930
رقم الانضمام: edsarx.1206.1930
قاعدة البيانات: arXiv