PCDD, PCDF, AND DL-PCB analysis in food: performance evaluation of the high-resolution gas chromatography/low-resolution tandem mass spectrometry technique using consensus-based samples

التفاصيل البيبلوغرافية
العنوان: PCDD, PCDF, AND DL-PCB analysis in food: performance evaluation of the high-resolution gas chromatography/low-resolution tandem mass spectrometry technique using consensus-based samples
المؤلفون: Anna Maria, Ingelido, Gianfranco, Brambilla, Annalisa, Abballe, Alessandro, di Domenico, Anna Rita, Fulgenzi, Nicola, Iacovella, Anna Laura, Iamiceli, Silvia, Valentini, Elena, De Felip
المصدر: Rapid communications in mass spectrometry : RCM. 26(3)
سنة النشر: 2012
مصطلحات موضوعية: Eels, Meat, Polychlorinated Dibenzodioxins, Sheep, Buffaloes, Polymers, Swine, Animal Feed, Polychlorinated Biphenyls, Sensitivity and Specificity, Gas Chromatography-Mass Spectrometry, Milk, Tandem Mass Spectrometry, Animals, Cattle, Chickens, Food Analysis, Benzofurans
الوصف: Due to safety concerns regarding dietary exposure to POPs, regulatory bodies are issuing detailed guidelines for testing for polychlorodibenzodioxins (PCDDs) and polychlorodibenzofurans (PCDFs) ('dioxins') and dioxin-like (DL)-PCBs in foods of animal origin. Determination of the aforesaid chemicals at regulatory levels requires highly selective and sensitive testing techniques. The new generation of low-resolution mass spectrometers (triple quadrupoles) allows very low levels of quantification to be reached (in the order of tens of femtograms), thus suggesting a potential for their application in food and feed analysis. The performance of the low-resolution tandem mass spectrometry (LRMS/MS) approach with triple quadrupoles was assessed on a qualified set of food samples from proficiency tests (PTs) and defense analysis. Accuracy was tested comparing the results with data from high-resolution mass spectrometry (HRMS) and with consensus values from PTs. The cumulative TEQ results were characterized by deviations not exceeding 15% of PCDD + PCDF, DL-PCB, and PCDD + PCDF + DL-PCB (TEQ(TOT)) reference consensus values (sample TEQ(TOT) range, 2.29-25.1 pgWHO-TEQ(97)/g fat). Congener analytical variabilities did not influence significantly the WHO-TEQ(97) outcome of the corresponding sample. This preliminary performance evaluation highlights the potential of LRMS/MS as a routine technique for quantitative analysis of PCDDs, PCDFs, and DL-PCBs in food.