Silicon photomultipliers as readout for a segmented Time-of-Flight plastic detector

التفاصيل البيبلوغرافية
العنوان: Silicon photomultipliers as readout for a segmented Time-of-Flight plastic detector
المؤلفون: H. Schaffner, S. Saha, J. Vesic, P. Bednarczyk, J. Gerl, M. Reese, M. Górska, S. Doublet, F. Ameil, M. L. Cortés, Norbert Pietralla
المساهمون: École Centrale de Lyon (ECL), Université de Lyon
المصدر: Nucl.Instrum.Meth.A
Nucl.Instrum.Meth.A, 2018, 899, pp.101-105. ⟨10.1016/j.nima.2018.05.031⟩
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Elsevier, 2018, 899, pp.101-105. ⟨10.1016/j.nima.2018.05.031⟩
بيانات النشر: HAL CCSD, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Nuclear and High Energy Physics, Ion beam, Physics::Instrumentation and Detectors, STRIPS, Scintillator, Silicon photomultiplier, 01 natural sciences, Time-of-flight measurement, Particle identification, law.invention, law, 0103 physical sciences, [PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det], 010306 general physics, Instrumentation, Heavy-ion detection, Physics, Plastic scintillator, 010308 nuclear & particles physics, business.industry, Detector, Time resolution, Time of flight, Optoelectronics, business, Beam (structure)
الوصف: International audience; Particle identification at radioactive ion beam facilities requires Time-of-Flight detectors with an optimal time resolution and high rate capability. Segmented plastic scintillators are a common option for such detectors. A promising approach to cope with the high segmentation of modern devices is the use of silicon photomultipliers (SiPMs) as readout of the Time-of-Flight detectors. A prototype device consisting of strips of plastic scintillator of 4.4 × 100 × 1 mm 3 readout at both ends by SiPMs of two different sizes was tested using a 124 Xe beam at 600 MeV/nucleon. Timing and time-over-threshold information were extracted. The time resolution of the prototype was found to vary with the applied voltage and the SiPM size. After optimizing the voltage, resolutions of 14.3(10) ps and 10.4(1) ps were obtained for SiPMs of 1 × 1 mm 2 and 3 × 3 mm 2 respectively. These results point to SiPMs being suitable as readout of plastic scintillators at radioactive ion beam facilities.
اللغة: English
تدمد: 0168-9002
DOI: 10.1016/j.nima.2018.05.031⟩
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fecd80ddd2f2647e3db30969aa6c9245
https://hal.archives-ouvertes.fr/hal-01817894
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....fecd80ddd2f2647e3db30969aa6c9245
قاعدة البيانات: OpenAIRE
الوصف
تدمد:01689002
DOI:10.1016/j.nima.2018.05.031⟩