Evaluation of Huawei smart wearables for detection of atrial fibrillation in patients following ischemic stroke:The Liverpool-Huawei Stroke Study

التفاصيل البيبلوغرافية
العنوان: Evaluation of Huawei smart wearables for detection of atrial fibrillation in patients following ischemic stroke:The Liverpool-Huawei Stroke Study
المؤلفون: Stephanie L. Harrison, Benjamin J.R. Buckley, Yalin Zheng, Andrew Hill, Thant Hlaing, Ruth Davies, Yutao Guo, Deirdre A. Lane, Gregory Y.H. Lip, Sylvia Choi, Sandra Elsheikh, Dimitrios Sagris, Martha Joddrell, Muath Alobaida, E. McCarthy, Elizabeth McCarthy, I. Eustace, Ian Eustace, K. Hoad, S.J. Katie Hoad, Sunil Jit R.J. Logantha, Garry McDowell, Alena Shantsila, Ying Gue, M Isanejad, I. Jones, Masoud Isanejad, Ian Jones
المصدر: Harrison, S L, Buckley, B J R, Zheng, Y, Hill, A, Hlaing, T, Davies, R, Guo, Y, Lane, D A, Lip, G Y H, Liverpool-Huawei Stroke Study Investigators, Choi, S, Elsheikh, S, Sagris, D, Joddrell, M, Alobaida, M, McCarthy, E, Eustace, I, Hoad, K, Logantha, S J R J, McDowell, G, Shantsila, A, Gue, Y, Isanejad, M & Jones, I 2023, ' Evaluation of Huawei smart wearables for detection of atrial fibrillation in patients following ischemic stroke : The Liverpool-Huawei Stroke Study ', American Heart Journal, vol. 257, pp. 103-110 . https://doi.org/10.1016/j.ahj.2022.12.004
سنة النشر: 2023
مصطلحات موضوعية: Cardiology and Cardiovascular Medicine
الوصف: BACKGROUND: Atrial fibrillation (AF) often remains undetected following stroke. Documenting AF is critical to initiate oral anticoagulation, which has proven benefit in reducing recurrent stroke and mortality in patients with AF. The accuracy and acceptability of using smart wearables to detect AF in patients following stroke is unknown.METHODS: The aims of the Liverpool-Huawei Stroke Study are to determine the effectiveness, cost-effectiveness and patient and staff acceptability of using Huawei smart wearables to detect AF following ischemic stroke. The study plans to recruit 1,000 adults aged ≥18 years following ischemic stroke from participating hospitals over 12 months. All participants will be asked to wear a Huawei smart band for 4 weeks postdischarge. If participants do not have access to a compatible smartphone required for the study, they will be provided with a smartphone for the 4-week AF monitoring period.RESULTS: Participants with suspected AF detected by the smart wearables, without previous known AF, will be referred for further evaluation. To determine the effectiveness of the Huawei smart wearables to detect AF, the positive predictive value will be determined. Patient acceptability of using this technology will also be examined. Additional follow-up assessments will be conducted at 6 and 12 months, and clinical outcomes recorded in relation to prevalent and incident AF post-stroke. The study opened for recruitment on May 30, 2022, and is currently open at 4 participating hospitals; the first 106 participants have been recruited. One further hospital is preparing to open for recruitment.CONCLUSIONS: This prospective study will examine the effectiveness and acceptability of the use of smart wearables in patients following ischemic stroke. This could have important implications for detection of AF and therefore, earlier prophylaxis for recurrent stroke. The study is registered on https://www.isrctn.com/ (Identifier ISRCTN30693819).
وصف الملف: application/pdf
اللغة: English
DOI: 10.1016/j.ahj.2022.12.004
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::fc78cebd7c353c89d50731a70f61b945
https://vbn.aau.dk/da/publications/7d5bc104-926b-4a5b-a085-33cf2e8b2dcb
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....fc78cebd7c353c89d50731a70f61b945
قاعدة البيانات: OpenAIRE
الوصف
DOI:10.1016/j.ahj.2022.12.004