Evaluation of visual quality after EVO-ICL implantation for hypermyopia

التفاصيل البيبلوغرافية
العنوان: Evaluation of visual quality after EVO-ICL implantation for hypermyopia
المؤلفون: Lianyun Bao, Zifang He, Qin Qin, Liping Yang, Zhenping Huang, Zhengcan Wu, Hui Chen
المصدر: Medicine
بيانات النشر: Ovid Technologies (Wolters Kluwer Health), 2019.
سنة النشر: 2019
مصطلحات موضوعية: Adult, Male, Phakic Intraocular Lenses, medicine.medical_specialty, Refractive error, Intraocular pressure, Visual acuity, genetic structures, Visual Acuity, Observational Study, Coma (optics), Astigmatism, Phakic intraocular lens, Young Adult, 03 medical and health sciences, Postoperative Complications, 0302 clinical medicine, Lens Implantation, Intraocular, Ophthalmology, Myopia, medicine, Humans, 030212 general & internal medicine, Intraocular Pressure, Retrospective Studies, business.industry, hypermyopia, Glare (vision), General Medicine, medicine.disease, visual quality, eye diseases, Spherical aberration, EVO-ICL, 030220 oncology & carcinogenesis, Quality of Life, Female, medicine.symptom, business, Research Article
الوصف: The purpose of this retrospective study was to evaluate the visual quality, objective scattering index, aberration, etc after Implantable Collamer Lens with center hole (EVO-ICL) implantation to treat patients with hypermyopia (diopter > −10 D). A total of 30 eyes underwent EVO-ICL implantation. The uncorrected distance visual acuity (UDVA), best-corrected visual acuity (BCVA), equivalent spherical degree, aberration, visual quality parameters, and corneal endothelial cell density were compared preoperative and postoperative. Fill in the National Eye Institute Refractive Error Quality of Life Instrument-42 before and after surgery. The modulation transfer function (MTF), Optical Quality Analysis System (OQAS) II values (OV 100%, 20%, 9%), and Stahl ratio 1 and 3 months after surgery were higher than the respective preoperative values. The objective scatter index value increased 1 week after surgery, but decreased 1 and 3 months after surgery compared with the preoperative values. Total aberration (TA), total low-order aberration (tLOAs), and defocus decreased at 1 week and 3 months after EVO-ICL implantation. Total high-order aberration (tHOAs) and spherical aberration were significantly increased 1 week after surgery and decreased 3 months after surgery, and the difference was statistically significant. Astigmatism, coma, and clover were not significantly different in each time period. TA, tLOAs, tHOAs, defocus, and spherical aberration were higher at 1 week than 3 months after surgery. At 3 months after surgery, the scores of the patients’ NEI-RQL-42 scale were all improved except that the glare was lower than that before surgery. There was no significant difference in the density of corneal endothelial cells before and 3 months after surgery. For patients with hypermyopia, the postoperative subjective and objective visual quality of EVO-ICL implantation was better than preoperative.
تدمد: 1536-5964
0025-7974
DOI: 10.1097/md.0000000000017677
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f6dc7e875f28e1d87b4a370ff5f34102
https://doi.org/10.1097/md.0000000000017677
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....f6dc7e875f28e1d87b4a370ff5f34102
قاعدة البيانات: OpenAIRE
الوصف
تدمد:15365964
00257974
DOI:10.1097/md.0000000000017677