Flexible direct-growth CNT biosensors

التفاصيل البيبلوغرافية
العنوان: Flexible direct-growth CNT biosensors
المؤلفون: Meng-Che Tu, Jing-Huei Huang, Yun-Tzu Chang, Pin Chang, Tri-Rung Yew
المصدر: Biosensors and Bioelectronics. 41:898-902
بيانات النشر: Elsevier BV, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Materials science, Conductometry, Biocompatibility, Biomedical Engineering, Biophysics, Nanotechnology, Biosensing Techniques, macromolecular substances, Carbon nanotube, Sensitivity and Specificity, law.invention, chemistry.chemical_compound, Parylene, law, Materials Testing, Electrochemistry, medicine, Humans, Particle Size, Bovine serum albumin, Serum Albumin, Immunoassay, biology, Nanotubes, Carbon, technology, industry, and agriculture, Reproducibility of Results, Equipment Design, General Medicine, Human serum albumin, Dielectric spectroscopy, Equipment Failure Analysis, chemistry, biology.protein, 1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide, Crystallization, Biosensor, Biotechnology, medicine.drug
الوصف: A biosensor was fabricated by growing carbon nanotubes (CNTs) directly on a polyimide flexible substrate at low temperatures (≤400 °C). A biocompatible polymer (poly(para-xylylene), parylene) was subsequently coated on the surface without CNTs as an insulator for future applications of flexible biosensors in in vivo sensing. The feasibility of the CNT flexible biosensor was demonstrated by quantitatively detecting human serum albumin (HSA). The CNT surface was modified with functional groups using UV–ozone, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC), and treated with N-hydroxysuccinimide (NHS) to improve the biocompatibility for the conjugation of protein. In addition, anti-HSA (AHSA) was used to capture HSA specifically, and bovine serum albumin (BSA) was applied to block the non-specific sites. The electrical properties of the biosensors applied with various HSA concentrations were measured and quantified using an electrochemical impedance spectroscopy system under AC conditions. The detection limit of the biosensor for HSA detection was approximately 3×10 −11 mg/ml. The proposed sensor has considerable potential for future application in wearable biosensors and implant detection.
تدمد: 0956-5663
DOI: 10.1016/j.bios.2012.09.049
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f389a374e3044f2961141b8a1d8e7c6a
https://doi.org/10.1016/j.bios.2012.09.049
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....f389a374e3044f2961141b8a1d8e7c6a
قاعدة البيانات: OpenAIRE
الوصف
تدمد:09565663
DOI:10.1016/j.bios.2012.09.049