Optimization of Echo Train Length in Non-contrast Enhanced MR Angiography for Clinical Examination of the Calf Arteries
العنوان: | Optimization of Echo Train Length in Non-contrast Enhanced MR Angiography for Clinical Examination of the Calf Arteries |
---|---|
المؤلفون: | Yoshio Machida, Ayako Fujimoto, Minami Aoba |
المصدر: | Japanese Journal of Radiological Technology. 76:689-698 |
بيانات النشر: | Japanese Society of Radiological Technology, 2020. |
سنة النشر: | 2020 |
مصطلحات موضوعية: | Peroneal Artery, medicine.diagnostic_test, Phantoms, Imaging, Systole, business.industry, Ultrasound, Diastole, Arteries, General Medicine, Imaging phantom, 030218 nuclear medicine & medical imaging, 03 medical and health sciences, 0302 clinical medicine, medicine.anatomical_structure, 030220 oncology & carcinogenesis, Angiography, medicine, Humans, business, Volunteer, Magnetic Resonance Angiography, Artery, Biomedical engineering |
الوصف: | Purpose Non-contrast magnetic resonanse angiography (MRA) using the three-dimensional electrocardiogram-synchronized fast spin echo method uses systolic and diastolic arterial signal differences. The method relies on the flow void signal of the arterial flow because of dephasing during systole. However, depiction of slow flow such as that in a calf artery was degraded because of insufficient dephasing during systole. In this study, we optimized echo train length (ETL) using a flow phantom and normal volunteers for clinical examination of the calf arteries. Methods Flow phantom and normal volunteer images were obtained with various ETLs (40, 50, 60, and 70). An averaged profile across the tube in the phantom was used for detailed investigation of flow dephasing. Visual evaluation was performed and signal intensity change along vessels was measured using normal volunteer images. Comparison with peak systolic velocity (PSV) measured using ultrasound equipment was also conducted. Results Results of the flow phantom and normal volunteer study indicated that the overall depictability was improved with ETL 60 and 70, which was higher than the standard value. Additionally, the visualization of the peroneal artery with low PSV of ETL 70 had better depictability than ETL 60. Conclusion This study suggested that ETL 70 might be better for clinical examination of the calf arteries. |
تدمد: | 1881-4883 0369-4305 |
DOI: | 10.6009/jjrt.2020_jjrt_76.7.689 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f04c4ebcc5277fa2b104eaae52574b28 https://doi.org/10.6009/jjrt.2020_jjrt_76.7.689 |
Rights: | OPEN |
رقم الانضمام: | edsair.doi.dedup.....f04c4ebcc5277fa2b104eaae52574b28 |
قاعدة البيانات: | OpenAIRE |
تدمد: | 18814883 03694305 |
---|---|
DOI: | 10.6009/jjrt.2020_jjrt_76.7.689 |