التفاصيل البيبلوغرافية
العنوان: |
Emittance Measurement with Double-Slit Method in CADS Injector-I |
المؤلفون: |
Meng, Cai, Geng, Huiping, Xue, Zhou, Yan, Fang, Yu, Lingda, Zhao, Yaliang |
المصدر: |
Scopus-Elsevier |
بيانات النشر: |
JACoW, Geneva, Switzerland, 2016. |
سنة النشر: |
2016 |
مصطلحات موضوعية: |
Physics::Accelerator Physics, 04 Hadron Accelerators, Accelerator Physics |
الوصف: |
The C-ADS accelerator is a CW (Continuous-Wave) proton linac with 1.5 GeV in beam energy, 10 mA in beam current, and 15 MW in beam power. CADS Injector-I accelerator is a 10-mA 10-MeV CW proton linac, which uses a 3.2-MeV normal conducting 4-Vane RFQ and superconducting single-spoke cavities for accelerating. The 5MeV test stand of CADS accelerator Injector I is composed of an ion source, a LEBT, a 325MHz RFQ, a MEBT, a cryogenic module (CM1) of seven SC spoke cavities (β=0.12) , seven SC solenoids, seven cold BPMs and a beam dump. Emittance measurement is very important for the understanding of beam behavior and matching to the next accelerating section. Detailed emittance measurement with double-slit method after CM1 are presented in this paper. Proceedings of the 7th Int. Particle Accelerator Conf., IPAC2016, Busan, Korea |
اللغة: |
English |
DOI: |
10.18429/jacow-ipac2016-mopoy031 |
URL الوصول: |
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::e90466c03477c208ffb7e11816951843 |
رقم الانضمام: |
edsair.doi.dedup.....e90466c03477c208ffb7e11816951843 |
قاعدة البيانات: |
OpenAIRE |