Concentrations and gas/particle partitioning of PCBs in Chicago

التفاصيل البيبلوغرافية
العنوان: Concentrations and gas/particle partitioning of PCBs in Chicago
المؤلفون: Thomas M. Holsen, Mustafa Odabasi, Nedim Vardar, Yücel Tasdemir
المساهمون: Uludağ Üniversitesi/Mühendislik Fakültesi/Çevre Mühendisliği Bölümü., Taşdemir, Yücel, AAG-9468-2021
المصدر: Environmental Pollution. 131:35-44
بيانات النشر: Elsevier BV, 2004.
سنة النشر: 2004
مصطلحات موضوعية: Meteorology, Vapor pressure, Health, Toxicology and Mutagenesis, Wind, Organic-compounds, Dry deposition, Toxicology, Troposphere, Prevailing winds, Green Bay, Environmental sciences & ecology, Vapor-pressure, Polycyclic aromatic-hydrocarbons, PCBs, Atmospheric polychlorinated-biphenyls, Gas-particle partitioning, Back trajectory, Chicago, Air Pollutants, Persistent organic pollutant, General Medicine, Particulates, TSP, Polychlorinated Biphenyls, Pollution, Lake-Michigan, Ambient air, Gas-phase, Aerosol, Environmental sciences, Partition coefficient, Environmental chemistry, Great-Lakes, Particle, Environmental science, Seasons, Environmental Monitoring
الوصف: Thirty seven air samples were collected in Chicago, IL from June to October 1995 and analyzed for gas and particle concentrations of polychlorinated biphenyls (PCBs). Lower molecular weight (MW) PCBs dominated the samples and on average 95% of the Sigma(50)PCB concentration (gas + particulate) was in the vapor phase. Sigma(50)PCB concentrations were classified based on prevailing winds (lake and land). The Sigma(50)PCB concentration varied between 0.42 and 5.21 ng/m(3) (1.80 +/- 1.70 ng/m(3)) for lake and 0.53 and 8.31 ng/m(3) (2.41 +/- 2.15 ng/m(3)) for land wind directions. Back trajectory analyses suggested that SW of Chicago can be an important local or regional source sector for PCBs. Partitioning between gas and particulate phases was modeled using the Junge-Pankow model. The measured particle phase concentrations for low MW PCBs were lower than those predicted by the model while the opposite was observed for high MW PCBs. Plots of gas/particle partition coefficient (log K-p) vs. subcooled liquid vapor pressure (log p(L)(0) had reasonable correlations for individual samples but the slope varied among the samples. Samples that originated from over the lake had higher slopes than samples that originated from over the land. (C) 2004 Elsevier Ltd. All rights reserved.
تدمد: 0269-7491
DOI: 10.1016/j.envpol.2004.02.031
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::dc33c6aa347cc013b7c66fc58d16d12d
https://doi.org/10.1016/j.envpol.2004.02.031
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....dc33c6aa347cc013b7c66fc58d16d12d
قاعدة البيانات: OpenAIRE
الوصف
تدمد:02697491
DOI:10.1016/j.envpol.2004.02.031