Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

التفاصيل البيبلوغرافية
العنوان: Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system
المؤلفون: Mona Ataee, Neema Bakhshalian, Shaya Sadeghi, Shahriar Shahab, Soodeh Sarikhani, Mahdis Mohammadpour
المصدر: Imaging Science in Dentistry
بيانات النشر: Korean Academy of Oral and Maxillofacial Radiology, 2014.
سنة النشر: 2014
مصطلحات موضوعية: Post Technique, Cone beam computed tomography, Poor prognosis, Materials science, Radiological and Ultrasound Technology, business.industry, Test group, fungi, technology, industry, and agriculture, Dentistry, chemistry.chemical_element, Tooth Fracture, Cone-Beam Computed Tomography, medicine.disease, Vertical root fracture, stomatognathic system, chemistry, medicine, Original Article, Radiology, Nuclear Medicine and imaging, business, General Dentistry, Titanium
الوصف: Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts. (Imaging Sci Dent 2014; 44: 89-94)
تدمد: 2233-7830
2233-7822
DOI: 10.5624/isd.2014.44.2.89
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d7dcf5cf447d4cf3b0c4884f62025578
https://doi.org/10.5624/isd.2014.44.2.89
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....d7dcf5cf447d4cf3b0c4884f62025578
قاعدة البيانات: OpenAIRE
الوصف
تدمد:22337830
22337822