Quantitative determination of total methamphetamine and active metabolites in rat tissue by liquid chromatography with tandem mass spectrometric detection

التفاصيل البيبلوغرافية
العنوان: Quantitative determination of total methamphetamine and active metabolites in rat tissue by liquid chromatography with tandem mass spectrometric detection
المؤلفون: Elizabeth M. Laurenzana, S. Michael Owens, Howard P. Hendrickson
المصدر: The AAPS Journal. 8:E709-E717
بيانات النشر: Springer Science and Business Media LLC, 2006.
سنة النشر: 2006
مصطلحات موضوعية: Male, Analyte, Electrospray, Chromatography, Chemistry, Coefficient of variation, Pharmaceutical Science, Meth, Methamphetamine, Tandem mass spectrometry, Article, Rats, Rats, Sprague-Dawley, chemistry.chemical_compound, Tandem Mass Spectrometry, medicine, Animals, Tissue Distribution, Trichloroacetic acid, Active metabolite, Chromatography, Liquid, medicine.drug
الوصف: High-throughput liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) methodology for the determination of methamphetamine (METH), amphetamine (AMP), 4-hydroxymethamphetamine (4-OH-METH), and 4-hydroxyamphetamine (4-OH-AMP) was developed and validated using simple trichloroacetic acid sample treatment. The method was validated in rat serum, brain, and testis. Lower limits-of-quantitation (LOQ) for METH and AMP were 1 ng x mL(-1) using positive ion electrospray tandem mass spectrometry (MS/MS). The accuracy of the method was within 25% of the actual values over a wide range of analyte concentrations. The within-assay precision was better than 12% (coefficient of variation). The method was linear over a wide dynamic range (0.3-1000 ng x mL(-1)). Quantitation was possible in all 3 matrices using only serum standards because of minimal matrix-associated ion effects or the use of an internal standard. Finally, the LC-MS/MS method was used to determine serum, brain, and testis METH and AMP concentrations during a subcutaneous infusion (5.6 mg kg(-1) day(-1)) of METH in rats. Concentrations of 4-OH-AMP and 4-OH-METH were below the LOQ in experimental samples. The bias introduced by using serum calibrators for the determination of METH and AMP concentrations in testis and brain was less than 8% and insignificant relative to the interanimal variability.
تدمد: 1550-7416
DOI: 10.1208/aapsj080480
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b3e64d1e1939009e5bb160cd50e6cc65
https://doi.org/10.1208/aapsj080480
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....b3e64d1e1939009e5bb160cd50e6cc65
قاعدة البيانات: OpenAIRE
الوصف
تدمد:15507416
DOI:10.1208/aapsj080480