Lower Limb Malrotation Is Regularly Present in Long-Leg Radiographs Resulting in Significant Measurement Errors

التفاصيل البيبلوغرافية
العنوان: Lower Limb Malrotation Is Regularly Present in Long-Leg Radiographs Resulting in Significant Measurement Errors
المؤلفون: Jens Schaumburger, Joachim Grifka, Clemens Baier, J. Matussek, Günther Maderbacher, Felix Greimel, Armin Keshmiri
المصدر: The Journal of Knee Surgery. 34:108-114
بيانات النشر: Georg Thieme Verlag KG, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, Rotation, Radiography, Lower limb, Weight-Bearing, Proximal tibia, 03 medical and health sciences, 0302 clinical medicine, Humans, Medicine, Orthopedics and Sports Medicine, Femur, Arthroplasty, Replacement, Knee, Aged, Aged, 80 and over, Orthodontics, 030222 orthopedics, Observational error, Tibia, business.industry, Bone Malalignment, 030229 sport sciences, Middle Aged, Confidence interval, Osteotomy, Lower Extremity, External rotation, Fibula, Orthopedic surgery, Female, Surgery, business
الوصف: Weight-bearing long-leg radiographs are commonly used in orthopaedic surgery. Measured parameters, however, change when radiographs are conducted in different rotational positions of the leg. It was hypothesized that rotational errors are regularly present in long-leg radiographs resulting in wrong measurements. In 100 consecutive long-leg radiographs conducted according to the method of Paley, rotation was assessed by fibular overlap. Angular parameters in radiographs (mechanical lateral proximal femoral angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), angle between the anatomical and mechanical femoral axis (AMA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal tibial angle (mLDTA), and the mechanical femoral and tibial axis (mFA–mTA) were measured and deviations related to malrotation calculated. An average internal rotation of 8 degrees was found in lower limbs showing a range between 29 degrees of internal and 22 degrees of external rotation. As a result, mean differences before and after rotational correction for measured parameters (mLPFA, mLDFA, AMA, mMPTA, mLDTA, mFA–mTA) ranged between 0.4 and 1.7 degrees (−2.1; 5.6 95% confidence interval [CI]). In conclusion, malrotation of lower limbs is regularly present in long-leg radiographs. As all measured parameters are influenced by malrotation, correct lower limb rotation needs to be verified.
تدمد: 1938-2480
1538-8506
DOI: 10.1055/s-0039-1693668
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b2e7f60dc888c8ce82a36998961c6da7
https://doi.org/10.1055/s-0039-1693668
رقم الانضمام: edsair.doi.dedup.....b2e7f60dc888c8ce82a36998961c6da7
قاعدة البيانات: OpenAIRE
الوصف
تدمد:19382480
15388506
DOI:10.1055/s-0039-1693668