مصطلحات موضوعية: Clinical Biochemistry, Pharmaceutical Science, Infrared spectroscopy, Spectrometry, Mass, Secondary Ion, 02 engineering and technology, Mass spectrometry, Spectrum Analysis, Raman, 01 natural sciences, Analytical Chemistry, Release agent, symbols.namesake, Drug Discovery, Spectroscopy, Fourier Transform Infrared, Calibration, Absorption (electromagnetic radiation), Process engineering, Spectroscopy, Chemistry, business.industry, 010401 analytical chemistry, Reproducibility of Results, Spectrometry, X-Ray Emission, Reference Standards, 021001 nanoscience & nanotechnology, 0104 chemical sciences, Characterization (materials science), Chemical species, Equipment and Supplies, symbols, Equipment Contamination, 0210 nano-technology, Raman spectroscopy, business, Stearic Acids
الوصف: There is a strong need in the medical device industry to decrease failure rates of biomedical devices by reducing the incidence of defect structures and contaminants during the production process. The detection and identification of defect structures and contaminants is crucial for many industrial applications. The present study exploits reference-free X-ray fluorescence (XRF) analysis as an analytical tool for the traceable characterization of surface contaminants of medical devices, in particular N,N'-ethylene-bis (stearamide), an ubiquitous compound used in many industrial applications as a release agent or friction reduction additive. Reference-free XRF analysis as primary method has been proven to be capable of underpinning all other applied methods since it yields the absolute mass deposition of the selected N,N'-ethylene-bis (stearamide) contaminant whilst X-ray absorption fine structure analysis determines the chemical species. Ambient vibrational spectroscopy and mass spectroscopy methodologies such as Fourier transform infrared, Raman, and secondary ion mass spectroscopy have been used in this systematic procedure providing an extensive range of complementary analyses. The calibration procedure described in this paper was developed using specially designed and fabricated model systems varying in thickness and substrate material. Furthermore, typical real medical devices such as both a polyethylene hip liner and a silver-coated wound dressing have been contaminated and investigated by these diverse methods, enabling testing of this developed procedure. These well-characterized samples may be used as calibration standards for bench top instrumentation from the perspective of providing traceable analysis of biomaterials and surface treatments. These findings demonstrate the potential importance and usefulness of combining complementary methods for a better understanding of the relevant organic materials.
تدمد: 1873-264X
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a27ea78ff3c3408650bd5dcc18af043a
https://pubmed.ncbi.nlm.nih.gov/29272815
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....a27ea78ff3c3408650bd5dcc18af043a
قاعدة البيانات: OpenAIRE