مصطلحات موضوعية: Detection limit, Chromatography, Starch, General Chemical Engineering, Sonication, Hydrophilic interaction chromatography, 010401 analytical chemistry, Extraction (chemistry), General Engineering, 04 agricultural and veterinary sciences, Mass spectrometry, Tandem mass spectrometry, 040401 food science, 01 natural sciences, Chloride, 0104 chemical sciences, Analytical Chemistry, chemistry.chemical_compound, 0404 agricultural biotechnology, chemistry, HPLC-MS, cation starch derivatives, QUAB, air sample, CTA, ETA, CHIM/01 - CHIMICA ANALITICA, medicine, medicine.drug
الوصف: The industrial processes of starch cationization are widely used and the workers must protect their health from the potential presence of toxic species, such as 2,3-epoxypropyltrimethylammonium chloride (ETA or Quab 151®) or 3-chloro-2-hydroxypropyltrimethylammonium chloride (CTA or Quab 188®) used during the industrial processes. In this study, a sensitive and fast chromatographic method for the identification and determination of these toxic species in samples placed in fixed air sampling positions near to the reactor of starch processing has been developed and fully validated. The method is based on hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry detection. The limits of detection are 3.0 ng mL−1 and 1.0 ng mL−1 for ETA and CTA, respectively, and the RSD% of the intraday (n = 5) and the interday (n = 35) precision of concentration determination are lower than 3.4% and 6.1%, respectively. The solid–liquid extraction procedure employed here is very simple (sonication) and fast (5 min) and allows obtaining reliable recovery values greater than 91.0%. No evidence of statistically significant matrix effects (at a 95% of confidence level) during the mass spectrometry analysis has been found. The method has been successfully applied to filter samples used in routine controls for the safety of workers involved in these type of industrial processes.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::a2794af0f3955fbb564f43e3414b8ce2
http://hdl.handle.net/10281/252973
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....a2794af0f3955fbb564f43e3414b8ce2
قاعدة البيانات: OpenAIRE