Study of Composite Insulator Sheds Subjected to Wheel Test

التفاصيل البيبلوغرافية
العنوان: Study of Composite Insulator Sheds Subjected to Wheel Test
المؤلفون: Zbigniew Ranachowski, J. Wańkowicz, J.L. Mikulski, S. Kucharski, Przemysław Ranachowski, M. Mackiewicz
المصدر: Archives of Metallurgy and Materials, Vol 62, Iss 2, Pp 679-686 (2017)
بيانات النشر: Walter de Gruyter GmbH, 2017.
سنة النشر: 2017
مصطلحات موضوعية: lcsh:TN1-997, Materials processing, Materials science, silicone rubber, Metals and Alloys, Industrial chemistry, composite insulators, 02 engineering and technology, 021001 nanoscience & nanotechnology, Composite insulators, Silicone rubber, tracking and erosion, chemistry.chemical_compound, 020303 mechanical engineering & transports, 0203 mechanical engineering, chemistry, lcsh:TA401-492, lcsh:Materials of engineering and construction. Mechanics of materials, Composite material, wheel test, 0210 nano-technology, electrical surface discharges, lcsh:Mining engineering. Metallurgy
الوصف: The paper presents investigation of the properties of the surface and the material stiffness – flexibility of series of samples taken from the sheds of the composite insulators. The insulators were previously subjected to wheel test. The wheel test and 1000 h salt fog test are regarded as alternative examination of the material resistance to the effects of electrical surface discharges. There were investigated two series of the samples of the composite insulators sheds. Examined specimens, made of HTV silicone rubber, were taken from the sheds of medium-voltage composite insulators of two different manufacturers. Insulators of both types passed the 1000 h salt fog test without reservation. Meanwhile, the wheel test can provide a basis for better distinguishing between physical properties of the tested materials. In the case of the insulators of one of the manufacturers the wheel test result was negative. Cross puncture effect of the sheds took place in several places. In addition, sheds were covered with dark coating of varying thicknesses. The results of the study indicated a significantly stronger influence of electrical and temperature factors on the sheds under investigations during the wheel test than in the case of the 1000 h salt fog test. It can be stated that these tests cannot be considered as alternative and it seems that wheel test enables better distinguishing between properties of the materials.
تدمد: 2300-1909
DOI: 10.1515/amm-2017-0101
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8d682def87540b04da65c4aa009a8874
https://doi.org/10.1515/amm-2017-0101
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....8d682def87540b04da65c4aa009a8874
قاعدة البيانات: OpenAIRE
الوصف
تدمد:23001909
DOI:10.1515/amm-2017-0101