Introduction of graphene oxide-supported multilayer-quantum dots nanofilm into multiplex lateral flow immunoassay: A rapid and ultrasensitive point-of-care testing technique for multiple respiratory viruses

التفاصيل البيبلوغرافية
العنوان: Introduction of graphene oxide-supported multilayer-quantum dots nanofilm into multiplex lateral flow immunoassay: A rapid and ultrasensitive point-of-care testing technique for multiple respiratory viruses
المؤلفون: Wenqi Wang, Xingsheng Yang, Zhen Rong, Zhijie Tu, Xiaochang Zhang, Bing Gu, Chongwen Wang, Shengqi Wang
المصدر: Nano Research. 16:3063-3073
بيانات النشر: Springer Science and Business Media LLC, 2022.
سنة النشر: 2022
مصطلحات موضوعية: General Materials Science, Electrical and Electronic Engineering, Condensed Matter Physics, Atomic and Molecular Physics, and Optics
الوصف: A lateral flow immunoassay (LFA) biosensor that allows the sensitive and accurate identification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other common respiratory viruses remains highly desired in the face of the coronavirus disease 2019 pandemic. Here, we propose a multiplex LFA method for the on-site, rapid, and highly sensitive screening of multiple respiratory viruses, using a multilayered film-like fluorescent tag as the performance enhancement and signal amplification tool. This film-like three-dimensional (3D) tag was prepared through the layer-by-layer assembly of highly photostable CdSe@ZnS-COOH quantum dots (QDs) onto the surfaces of monolayer graphene oxide nanosheets, which can provide larger reaction interfaces and specific active surface areas, higher QD loads, and better luminescence and dispersibility than traditional spherical fluorescent microspheres for LFA applications. The constructed fluorescent LFA biosensor can simultaneously and sensitively quantify SARS-CoV-2, influenza A virus, and human adenovirus with low detection limits (8 pg/mL, 488 copies/mL, and 471 copies/mL), short assay time (15 min), good reproducibility, and high accuracy. Moreover, our proposed assay has great potential for the early diagnosis of respiratory virus infections given its robustness when validated in real saliva samples.Supplementary material (Section S1 Experimental section, Section S2 Calculation of the maximum number of QDs on the GO@TQD nanofilm, Section S3 Optimization of the LFA method, and Figs. S1-S17 mentioned in the main text) is available in the online version of this article at 10.1007/s12274-022-5043-6.
تدمد: 1998-0000
1998-0124
DOI: 10.1007/s12274-022-5043-6
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7eaeec7eeda041e2ad08649b6418392d
https://doi.org/10.1007/s12274-022-5043-6
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....7eaeec7eeda041e2ad08649b6418392d
قاعدة البيانات: OpenAIRE
الوصف
تدمد:19980000
19980124
DOI:10.1007/s12274-022-5043-6