Adopting Duplex Sequencing™ Technology for Genetic Toxicity Testing: A Proof-of-Concept Mutagenesis Experiment with N-Ethyl-N-Nitrosourea (ENU)-Exposed Rats

التفاصيل البيبلوغرافية
العنوان: Adopting Duplex Sequencing™ Technology for Genetic Toxicity Testing: A Proof-of-Concept Mutagenesis Experiment with N-Ethyl-N-Nitrosourea (ENU)-Exposed Rats
المؤلفون: Stephanie L. Smith-Roe, Cheryl A. Hobbs, Victoria Hull, J. Todd Auman, Leslie Recio, Michael A. Streicker, Miriam V. Rivas, Gabriel A. Pratt, Fang Yin Lo, Jacob E. Higgins, Elizabeth K. Schmidt, Lindsey N. Williams, Daniela Nachmanson, Charles C. Valentine, Jesse J. Salk, Kristine L. Witt
المصدر: bioRxiv
بيانات النشر: Cold Spring Harbor Laboratory, 2023.
سنة النشر: 2023
مصطلحات موضوعية: Article
الوصف: Duplex sequencing (DuplexSeq) is an error-corrected next-generation sequencing (ecNGS) method in which molecular barcodes informatically link PCR-copies back to their source DNA strands, enabling computational removal of errors by comparing grouped strand sequencing reads. The resulting background of less than one artifactual mutation per 107nucleotides allows for direct detection of somatic mutations. TwinStrand Biosciences, Inc. has developed a DuplexSeq-based mutagenesis assay to sample the rat genome, which can be applied to genetic toxicity testing. To evaluate this assay for early detection of mutagenesis, a time-course study was conducted using male Hsd:Sprague Dawley SD rats (3 per group) administered a single dose of 40 mg/kg N-ethyl-N-nitrosourea (ENU) via gavage, with mutation frequency (MF) and spectrum analyzed in stomach, bone marrow, blood, and liver tissues at 3 h, 24 h, 7 d, and 28 d post-exposure. Significant increases in MF were observed in ENU-exposed rats as early as 24 h for stomach (site of contact) and bone marrow (a highly proliferative tissue) and at 7 d for liver and blood. The canonical, mutational signature of ENU was established by 7 d post-exposure in all four tissues. Interlaboratory analysis of a subset of samples from different tissues and time points demonstrated remarkable reproducibility for both MF and spectrum. These results demonstrate that MF and spectrum can be evaluated successfully by directly sequencing targeted regions of DNA obtained from various tissues, a considerable advancement compared to currently usedin vivogene mutation assays.HIGHLIGHTSDuplexSeq is an ultra-accurate NGS technology that directly quantifies mutationsENU-dependent mutagenesis was detected 24 h post-exposure in proliferative tissuesMultiple tissues exhibited the canonical ENU mutation spectrum 7 d after exposureResults obtained with DuplexSeq were highly concordant between laboratoriesThe Rat-50 Mutagenesis Assay is promising for applications in genetic toxicology
DOI: 10.1101/2023.05.08.539833
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7bc6e7afac422b90213086f574be3047
https://doi.org/10.1101/2023.05.08.539833
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....7bc6e7afac422b90213086f574be3047
قاعدة البيانات: OpenAIRE
الوصف
DOI:10.1101/2023.05.08.539833