Combined application of dispersive liquid–liquid microextraction based on the solidification of floating organic droplets and charged aerosol detection for the simple and sensitive quantification of macrolide antibiotics in human urine

التفاصيل البيبلوغرافية
العنوان: Combined application of dispersive liquid–liquid microextraction based on the solidification of floating organic droplets and charged aerosol detection for the simple and sensitive quantification of macrolide antibiotics in human urine
المؤلفون: Sung Won Kwon, Soon-Sun Hong, Sora Park, Jing Li, Jeong Hill Park, Shaodong Jia, Jeongmi Lee, Yeonsuk Ryu, Il Ho Park
المصدر: Journal of Pharmaceutical and Biomedical Analysis. 86:204-213
بيانات النشر: Elsevier BV, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Aerosols, Detection limit, Chromatography, Liquid Phase Microextraction, Precipitation (chemistry), Chemistry, Organic solvent, Clinical Biochemistry, Extraction (chemistry), Combined use, Analytical chemistry, Pharmaceutical Science, Urine, Anti-Bacterial Agents, Analytical Chemistry, Aerosol, Drug Discovery, Humans, Liquid liquid, Macrolides, Spectroscopy
الوصف: A novel analytical method combining dispersive liquid-liquid microextraction based on the solidification of floating organic droplets (DLLME-SFO) and liquid chromatography with charged aerosol detection (LC-CAD) was established. For the first time, CAD was applied for the detection of macrolide antibiotics lacking chromophores. Parameters influencing the microextraction efficiency were systematically investigated, and the optimized microextraction conditions yielded high enrichment factors in the range of 60-106. The combined application of DLLME-SFO and LC-CAD provided the sensitivity of the method, expressed as the limit of detection (LOD), as low as 10 to 40ngmL(-1) and intra-day and inter-day precisions below 8.7% and 12.6%, respectively. The measured absolute recovery values were approximately 100%, indicating that the extraction efficiency was very high. Direct comparisons of the liquid-liquid extraction and organic solvent precipitation methods demonstrated that the proposed method was more sensitive, specific, rapid, and environmentally friendly for the determination of five macrolide antibiotics in human urine. The results suggest that the combined use of DLLME-SFO and LC-CAD may be applicable to the analysis of various compounds with poor to no chromophores in complex matrices.
تدمد: 0731-7085
DOI: 10.1016/j.jpba.2013.07.024
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::77b483b54aec85b3a4b81c74589f7979
https://doi.org/10.1016/j.jpba.2013.07.024
رقم الانضمام: edsair.doi.dedup.....77b483b54aec85b3a4b81c74589f7979
قاعدة البيانات: OpenAIRE
الوصف
تدمد:07317085
DOI:10.1016/j.jpba.2013.07.024