مصطلحات موضوعية: Male, Formic acid, Calibration curve, Clinical Biochemistry, Ethyl acetate, Pharmaceutical Science, Crystallography, X-Ray, Peptides, Cyclic, 01 natural sciences, Analytical Chemistry, Rats, Sprague-Dawley, chemistry.chemical_compound, Pharmacokinetics, Tandem Mass Spectrometry, In vivo, Drug Discovery, Animals, Spectroscopy, chemistry.chemical_classification, Chromatography, 010405 organic chemistry, 010401 analytical chemistry, Selected reaction monitoring, Cyclic peptide, Rats, 0104 chemical sciences, chemistry, Quantitative analysis (chemistry), Chromatography, Liquid
الوصف: Hepatocellular carcinoma (HCC) is the second leading cause of cancer-related death worldwide. The discovery of new anticancer compounds is of great significance. GG-8-6, cyclo-(Val1-Leu2-Pro3-Ile4-Leu5-Leu6-Leu7-Val8-Leu9), a new synthetic cyclic peptide, might be a potential candidate for developing new anti-HCC drugs. GG-8-6 shares no structural homology to current anti-HCC drugs. Therefore, it was necessary to develop a quantitative method for the determination of GG-8-6 in vivo. Herein, a simple, specific and sensitive liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of GG-8-6 in rat plasma. GG-8-6 and the internal standard (IS), A6, cyclo-(Val1-Leu2-Pro3-Ala4-Leu5-Leu6-Leu7-Val8-Leu9), were extracted from rat plasma by ethyl acetate. Chromatographic separation was performed on an Agilent Eclipse XDB-C18 column (4.6 × 150 mm, 5 μm) with a mobile phase consisting of acetonitrile-water containing 0.1% formic acid (90:10, v/v) with isocratic elution at a flow rate of 0.5 mL/min for 8.0 min. Multiple reaction monitoring (MRM) mode was performed with ion pairs of m/z: 974.8 → 861.8 for GG-8-6 and 932.7 → 819.8 for A6. The selectivity, matrix effects, recovery, intra- and inter-day precision and accuracy were validated with acceptable results in accordance with the US Food and Drug Administration guidelines. The calibration curve was linear (r2 > 0.99) over a concentration range of 1–1000 ng/mL with a lower limit of quantification (LLOQ) of 1 ng/mL. The method was successfully applied to the pharmacokinetic study of GG-8-6 in rats.
تدمد: 0731-7085
DOI: 10.1016/j.jpba.2018.06.057
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::72b6f70ee0fd6a521a73a3bdd36218f4
https://doi.org/10.1016/j.jpba.2018.06.057
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....72b6f70ee0fd6a521a73a3bdd36218f4
قاعدة البيانات: OpenAIRE
الوصف
تدمد:07317085
DOI:10.1016/j.jpba.2018.06.057