Qualitative confirmation of 9 synthetic cannabinoids and 20 metabolites in human urine using LC-MS/MS and library search

التفاصيل البيبلوغرافية
العنوان: Qualitative confirmation of 9 synthetic cannabinoids and 20 metabolites in human urine using LC-MS/MS and library search
المؤلفون: Xiaohong Chen, Marilyn A. Huestis, Hua-fen Liu, Ariane Wohlfarth, Karl B. Scheidweiler
المصدر: Analytical chemistry. 85(7)
سنة النشر: 2013
مصطلحات موضوعية: Detection limit, Analyte, Chromatography, Chemistry, Formic acid, Cannabinoids, Illicit Drugs, Selected reaction monitoring, Tandem mass spectrometry, Mass spectrometry, Article, Analytical Chemistry, Substance Abuse Detection, chemistry.chemical_compound, Limit of Detection, Tandem Mass Spectrometry, Enzymatic hydrolysis, Synthetic cannabinoids, medicine, Humans, medicine.drug, Chromatography, Liquid
الوصف: Synthetic cannabinoids are an emerging illicit drug class. The variety of available substances is large and ever-changing, making it difficult for laboratories to remain current. We present a qualitative LC-MS/MS method identifying urinary metabolites of JWH-018, JWH-073, JWH-081, JWH-122, JWH-200, JWH-210, JWH-250, RCS-4, and AM2201 and the parent compounds JWH-018, JWH-073, JWH-081, JWH-122, JWH-210, JWH-250, RCS-4, AM2201, and MAM2201.After enzymatic hydrolysis, urinary proteins were precipitated with acetonitrile. Chromatography utilized a 10 min gradient on a Kinetex XB-C18 column with 0.1% formic acid in water and acetonitrile. Scheduled multiple reaction monitoring "survey scans" were followed by information-dependent acquisition-enhanced product ion scan experiments on an ABSciex 5500 QTRAP mass spectrometer. Analytes were identified by software-assisted library searching against reference spectra.The method was fully validated, including proof of selectivity (no exogenous or endogenous interferences were observed), assessment of matrix effects (95-122%) and recovery (53-95%), determination of limits of detection (0.5-10 ng/mL), carry-over studies (thresholds between 100 and 1000 ng/mL), and determination of autosampler stability (samples were stable for at least 3 days). Hydrolysis efficiency was thoroughly investigated for a wide range of glucuronides and for the reference standard, JWH-018 5-hydroxypentyl glucuronide.
تدمد: 1520-6882
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::709ca3095d5f53b7831fbf92313ecc11
https://pubmed.ncbi.nlm.nih.gov/23458260
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....709ca3095d5f53b7831fbf92313ecc11
قاعدة البيانات: OpenAIRE