Method of blood pressure measurement in neonates and infants: a systematic review and analysis |
المؤلفون: |
Ebru Ergenekon, Simin K. Baygani, Janis M. Dionne, Varsha Bhatt-Mehta, Dina Apele-Freimane, Luana Pesco Koplowitz, Heike Rabe, Stephen Bremner, Hiroko Iwami, Martin Kluckow, Mark A. Turner, Eugene M. Dempsey, Agnes Klein, Beau Batton |
بيانات النشر: |
Elsevier, 2020. |
سنة النشر: |
2020 |
مصطلحات موضوعية: |
Measurement method, medicine.medical_specialty, Mean arterial pressure, business.industry, Intra arterial pressure, Diastole, Infant, Newborn, Infant, Blood Pressure Determination, Cochrane Library, 03 medical and health sciences, RJ0251, 0302 clinical medicine, Blood pressure, Bp monitoring, 030225 pediatrics, Internal medicine, Pediatrics, Perinatology and Child Health, Cuff, Practice Guidelines as Topic, medicine, Cardiology, Humans, 030212 general & internal medicine, business |
الوصف: |
Objectives: To determine the recommended blood pressure (BP) measurement methods in neonates after systematically analyzing the international literature regarding proper BP cuff size and measurement location and method.\ud Study Design: A literature search was conducted in MEDLINE, PubMed, Embase, Cochrane Library and CINAHL from 1946 to 2017 on BP in neonates < 3 months of age (PROSPERO ID CRD42018092886). Study data was extracted and analyzed with separate analysis of Bland-Altman studies comparing measurement methods.\ud Results: Of 3587 non-duplicate publications identified, 34 were appropriate for inclusion in the analysis. Four studies evaluating BP cuff size support a recommendation for a cuff width to arm circumference ratio of ~0.5. Studies investigating measurement location identified the upper arm as the most accurate and least variable location for oscillometric BP measurement. Analysis of studies using Bland-Altman methods for comparison of intra-arterial to oscillometric BP measurement show that the two methods correlate best for mean arterial pressure (MAP) whereas systolic BP (SBP) by the oscillometric method tends to over-estimate intra-arterial SBP. Compared to intra-arterial methods, SBP, diastolic BP, and MAP by oscillometric methods are less accurate and precise, especially in neonates with a MAP |
وصف الملف: |
application/pdf |
اللغة: |
English |
تدمد: |
0022-3476 |
URL الوصول: |
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6828f07bec6a99bc92ccc854adb6fbab |
Rights: |
OPEN |
رقم الانضمام: |
edsair.doi.dedup.....6828f07bec6a99bc92ccc854adb6fbab |
قاعدة البيانات: |
OpenAIRE |