Validation of the bovine blood calcium checker as a rapid and simple measuring tool for the ionized calcium concentration in cattle

التفاصيل البيبلوغرافية
العنوان: Validation of the bovine blood calcium checker as a rapid and simple measuring tool for the ionized calcium concentration in cattle
المؤلفون: Marina Otsuka, Akitoyo Nishikawa, Kenji Tsukano, Keiko Ikeda, Ichiro Yasutomi, Hisashi Funakura, Kaede Takagi, Satoshi Kawamoto, Kazuyuki Suzuki, Yoshiki Murakami, Nao Kondo
المصدر: The Journal of Veterinary Medical Science
بيانات النشر: 日本獣医学会, 2021.
سنة النشر: 2021
مصطلحات موضوعية: Calcium metabolism, Spectrum analyzer, Hematologic Tests, Clinical Pathology, Chromatography, Full Paper, General Veterinary, Blood gas analyzer, Cattle Diseases, chemistry.chemical_element, ion-selective electrode, Calcium, hypocalcemia, ionized calcium, chemistry, cattle, point-of-care, Bovine blood, Animals, Female, Blood Gas Analysis, Whole blood, Field conditions
الوصف: Point-of-care (POC) devices that veterinary practitioners can use to easily and rapidly measure blood ionized calcium (iCa) levels in cows immediately after withdrawing a blood sample on the dairy farm are needed. Aims of present studies was to compare the commercially available ion-selective electrode handheld iCa meter (bovine blood iCa checker) with the benchtop blood gas analyzer GEM premier 3500 and handheld analyzer i-STAT 1. Sixty-two paired-point whole blood samples were obtained from three cows with hypocalcemia experimentally induced by Na2-EDTA infusion. Whole blood samples were also obtained from the 36 cows kept on a farm in field conditions. The results using the bovine blood iCa checker correlated with those using the GEM premier 3500 and i-STAT 1. Bovine blood iCa checker was “compatible” with the GEM premier 3500 and i-STAT 1 because the frequency of differences between the measurements within ± 20% of the mean were 100% (65/65, >75%) and 90.8% (59/65, >75%), respectively. In the field trial, the blood iCa concentration measured by the bovine blood Ca checker was significantly positively correlated with that measured by the i-STAT 1 portable analyzer. Bovine blood iCa checker was “compatible” with the i-STAT 1 because the frequency of differences between the measurements within ± 20% of the mean was 100% (36/36, >75%). Results from these findings, the bovine blood iCa checker may be applied as a simplified system to measure the iCa concentration in bovine whole blood.
اللغة: English
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::6810e20e6d3d74067ed70e77c57f5e25
http://hdl.handle.net/10659/00007410
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....6810e20e6d3d74067ed70e77c57f5e25