Geometric control of 3D needle steering in soft-tissue

التفاصيل البيبلوغرافية
العنوان: Geometric control of 3D needle steering in soft-tissue
المؤلفون: Ron S. Sloboda, Nawaid Usmani, Mahdi Tavakoli, Mohsen Khadem, Carlos Rossa
المصدر: Khadem, M, Rossa, C, Usmani, N, Sloboda, R S & Tavakoli, M 2019, ' Geometric control of 3D needle steering in soft-tissue ', Automatica, vol. 101, pp. 36-43 . https://doi.org/10.1016/j.automatica.2018.11.018
سنة النشر: 2019
مصطلحات موضوعية: Equilibrium point, Nonholonomic system, 0209 industrial biotechnology, Mean squared error, Computer science, 020208 electrical & electronic engineering, 02 engineering and technology, Nonlinear control, Imaging phantom, Autonomous control, Nonlinear system, 020901 industrial engineering & automation, Geometric approaches, Control theory, Control and Systems Engineering, 0202 electrical engineering, electronic engineering, information engineering, Point (geometry), Electrical and Electronic Engineering, Medical applications, Robot control
الوصف: In this paper, a 3D automated needle steering system is presented that can enhance the performance of needle-based procedures. The system comprises a nonholonomic needle steering model and a nonlinear controller for 3D needle steering. First, a reduced-order needle steering model is presented. Next, a geometric reduction procedure is carried out to present the nonlinear control system in a transformed format. Finally, the transformed model is used to design a two-step controller. The controller first stabilizes the system on an equilibrium manifold of the system and later employs a switching law to stabilize it on an equilibrium point in the manifold. The former performs insertion of the needle up to a desired depth and the latter performs retraction/insertion motion that guides the needle toward a desired point at the given depth. Validation experiments are performed on a phantom and ex-vivo animal tissues and the results are compared with manual needle insertions performed by skilled surgeons. The mean error of our 3D needle steering system is 60% less than manual needle insertions.
وصف الملف: application/pdf
اللغة: English
DOI: 10.1016/j.automatica.2018.11.018
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::67c0ef4c5147f289db5a59929137bda9
https://www.pure.ed.ac.uk/ws/files/78358454/Geometric_control_of_3d_needle_steering_in_soft_tissue.pdf
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....67c0ef4c5147f289db5a59929137bda9
قاعدة البيانات: OpenAIRE
الوصف
DOI:10.1016/j.automatica.2018.11.018