Preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty with patient-specific cartilage thickness measurement

التفاصيل البيبلوغرافية
العنوان: Preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty with patient-specific cartilage thickness measurement
المؤلفون: Kayhan Turan, Yalkin Camurcu, Murat Kezer, Yunus Uysal, Yusuf Onur Kizilay, Abdulaziz Temiz
المصدر: Journal of Robotic Surgery. 17:979-985
بيانات النشر: Springer Science and Business Media LLC, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Health Informatics, Surgery
الوصف: This study aimed to assess the preliminary outcomes of kinematically aligned robot-assisted total knee arthroplasty (TKA) with patient-specific cartilage thickness measurement. Patients who underwent kinematically aligned robot-assisted TKA were included in this study. Robot-assisted total knee arthroplasties were performed by NAVIO Surgical System (SmithNephew, Memphis, USA), an image-free handheld robotic system. The kinematic alignment technique was performed according to our intraoperative cartilage thickness measurement technique. Hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), joint-line orientation angle (JLOA), and joint-line convergence angle (JLCA) were measured through standing full-length anteroposterior radiographs. Knee Injury and Osteoarthritis Outcome Score, Oxford score, VAS pain and satisfaction score, and Forgotten Joint Score were used to assess clinical outcomes. A total of 142 knees of 109 patients (92 females and 17 males) were evaluated in this study. There was a significant correction in HKA, JLCA, and mMPTA postoperatively (p ≤0.001, 0.001, and 0.029, respectively). We observed no significant change in mLDFA and JLOA measurements. All clinical scores significantly increased at the latest follow-up. Our results demonstrated that kinematically aligned robot-assisted TKA with patient-specific cartilage thickness measurement demonstrated no significant change in mLDFA and JLOA, as expected; however, significantly corrected the deformity in HKA, mMPTA, and JLCA measurements.
تدمد: 1863-2491
DOI: 10.1007/s11701-022-01503-9
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5af2eec3d667788b0a98b58c71707bbb
https://doi.org/10.1007/s11701-022-01503-9
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....5af2eec3d667788b0a98b58c71707bbb
قاعدة البيانات: OpenAIRE
الوصف
تدمد:18632491
DOI:10.1007/s11701-022-01503-9