Innovative colorimetric sensors for the detection of nitrogen trichloride at ppb level in swimming pools

التفاصيل البيبلوغرافية
العنوان: Innovative colorimetric sensors for the detection of nitrogen trichloride at ppb level in swimming pools
المؤلفون: E. Chevallier, A.-M. Laurent, P. Karpe, T-H. Nguyen, T.-H. Tran-Thi, Cl. Beaubestre, Julien Garcia, Trung-Hieu Nguyen
المساهمون: ETHERA, Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Centre National de la Recherche Scientifique (CNRS), Laboratoire Francis PERRIN (LFP - URA 2453), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS), Laboratoire d'Hygiène de la Ville de Paris, Ville de Paris
المصدر: Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical, Elsevier, 2013, 187, pp.622-629. ⟨10.1016/j.snb.2013.07.041⟩
Sensors and Actuators B: Chemical, 2013, 187, pp.622-629. ⟨10.1016/j.snb.2013.07.041⟩
بيانات النشر: Elsevier BV, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Pollution, media_common.quotation_subject, 01 natural sciences, Nanoporous matrices, Atmosphere, 03 medical and health sciences, chemistry.chemical_compound, 0302 clinical medicine, Materials Chemistry, Electrical and Electronic Engineering, Instrumentation, Air quality index, Nitrogen trichloride, media_common, Pollutant, Colorimetric sensors, Chemistry, 010401 analytical chemistry, Metals and Alloys, Trap (plumbing), Condensed Matter Physics, 030210 environmental & occupational health, Swimming pools, 0104 chemical sciences, Surfaces, Coatings and Films, Electronic, Optical and Magnetic Materials, [CHIM.THEO]Chemical Sciences/Theoretical and/or physical chemistry, Environmental chemistry, Analytical procedures
الوصف: International audience; The development of new chemical sensors for the direct detection of nitrogen trichloride, NCl3, a toxic pollutant present in the atmosphere of indoor swimming pools, is described. These innovative chemical and colorimetric sensors are based on the use of nanoporous matrices doped with probe-molecules, which act as sponges to trap the targeted pollutant and turn from transparent to pink-violet. These sensors can detect NCl3 at ppb level within 15 min in humid atmosphere. Due to the fast change of color, visible with naked eyes, these sensors can be used to detect peaks of pollution and to monitor the air quality of indoor pools in public or private area. The technology was transferred from Francis Perrin Laboratory (LFP) to ETHERA, a CEA-CNRS4 spin-off, which optimizes both the sensor synthesis for mass production and the quality control procedures needed for marketing. Validation of analytical procedures and sensor response in real environment is accomplished via a campaign of NCl3 measurements in a Parisian swimming pool.
تدمد: 0925-4005
DOI: 10.1016/j.snb.2013.07.041
DOI: 10.1016/j.snb.2013.07.041⟩
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4caa4fa83468864644618bc77be6d541
https://doi.org/10.1016/j.snb.2013.07.041
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....4caa4fa83468864644618bc77be6d541
قاعدة البيانات: OpenAIRE
الوصف
تدمد:09254005
DOI:10.1016/j.snb.2013.07.041