Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma

التفاصيل البيبلوغرافية
العنوان: Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma
المؤلفون: Laura Morales-Fernandez, Jose M. Martinez-de-la-Casa, Federico Saenz-Frances, Julian Garcia-Feijoo, S. García-Sáenz, P. Pérez-García, Rosario Gómez de Liaño
المصدر: E-Prints Complutense. Archivo Institucional de la UCM
Universidad Europea (UEM)
بيانات النشر: Ovid Technologies (Wolters Kluwer Health), 2021.
سنة النشر: 2021
مصطلحات موضوعية: Applanation tonometry, Intraocular pressure, medicine.medical_specialty, genetic structures, Manometry, Glaucoma, Negative association, Cornea, Corneal hysteresis, Tonometry, Ocular, Ophthalmology, Humans, Medicine, In patient, Intraocular Pressure, business.industry, Primary congenital glaucoma, REBOUND TONOMETRY, medicine.disease, eye diseases, Biomechanical Phenomena, Oftalmología, sense organs, business
الوصف: Objective: To assess the influence of corneal biomechanics on intraocular pressure (IOP) measurements made with the Icare200 (IC200) rebound tonometer and the Perkins hand-held applanation tonometer in patients with primary congenital glaucoma (PCG). Materials and methods: 40 PCG patients and 40 healthy controls, age and gender-matched, were recruited. IOP was measured with the Ocular Response Analyzer (IOPc, IOPg), Icare200 and Perkins. The variables age, IOP, corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), best corrected visual acuity, spherical equivalent, medications and glaucoma surgeries were recorded for each subject. Uni and multivariate analysis were used to detect effects of variables on IOP measurements. Results: Mean CCT was 545.65±71.88 μm in PCG vs. 558.78±27.58 μm in controls (p=0.284). CH and CRF were significantly lower in PCG group than in control group: mean CH 8.11±1.69 mmHg vs. 11.15±1.63 mmHg (p
وصف الملف: application/pdf
تدمد: 1057-0829
DOI: 10.1097/ijg.0000000000001913
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::49748b00d08e954da530249a4bf202dd
https://doi.org/10.1097/ijg.0000000000001913
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....49748b00d08e954da530249a4bf202dd
قاعدة البيانات: OpenAIRE
الوصف
تدمد:10570829
DOI:10.1097/ijg.0000000000001913