In vivo 783-channel diffuse reflectance imaging system and its application

التفاصيل البيبلوغرافية
العنوان: In vivo 783-channel diffuse reflectance imaging system and its application
المؤلفون: Byung-Cheon Lee, Gilwon Yoon, Kwang-Sup Soh, Yong-Hui Han, Byung Soo Ahn, Joon-Mo Yang
المصدر: Applied Optics. 46:5991
بيانات النشر: The Optical Society, 2007.
سنة النشر: 2007
مصطلحات موضوعية: Normalization (statistics), Optics and Photonics, Materials science, Channel (digital image), Materials Science (miscellaneous), Electrons, Image processing, Sensitivity and Specificity, Signal, Industrial and Manufacturing Engineering, Imaging phantom, Diffusion, Optics, Image Processing, Computer-Assisted, Calibration, Animals, Humans, Business and International Management, Skin, Models, Statistical, Phantoms, Imaging, business.industry, Muscles, Reproducibility of Results, Equipment Design, Radiography, Diffuse reflection, business, Biological imaging, Chickens
الوصف: A fiber-based reflectance imaging system was constructed to produce in vivo absorption spectroscopic images of biological tissues with diffuse light in the cw domain. The principal part of this system is the 783-channel fiber probe, composed of 253 illumination fibers and 530 detection fibers distributed in a 20x20 mm square region. During illumination with the 253 illumination fibers, diffuse reflected lights are collected by the 530 detection fibers and recorded simultaneously as an image with an electron multiplying CCD camera for fast data acquisition. After signal acquisition, a diffuse reflectance image was reconstructed by applying the spectral normalization method we devised. To test the applicability of the spectral normalization, we conducted two phantom experiments with chicken breast tissue and white Delrin resin by using animal blood as an optical inhomogeneity. In the Delrin phantom experiment, we present images produced by two methods, spectral normalization and reference signal normalization, along with a comparison of the two. To show the feasibility of our system for biomedical applications, we took images of a human vein in vivo with the spectral normalization method.
تدمد: 1539-4522
0003-6935
DOI: 10.1364/ao.46.005991
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3599e7b990e8dbbf2741c3db8a4367bc
https://doi.org/10.1364/ao.46.005991
رقم الانضمام: edsair.doi.dedup.....3599e7b990e8dbbf2741c3db8a4367bc
قاعدة البيانات: OpenAIRE
الوصف
تدمد:15394522
00036935
DOI:10.1364/ao.46.005991