Transoral robotic-assisted supracricoid partial laryngectomy with cricohyoidoepiglottopexy: Procedure development and outcomes of initial cases

التفاصيل البيبلوغرافية
العنوان: Transoral robotic-assisted supracricoid partial laryngectomy with cricohyoidoepiglottopexy: Procedure development and outcomes of initial cases
المؤلفون: Kishore Sandu, Philippe Gorphe, Christian Simon, Benoit Morisod, Anne-Claude Guinchard, Valérie Schweizer
المصدر: Head & Neck. 40:2254-2262
بيانات النشر: Wiley, 2018.
سنة النشر: 2018
مصطلحات موضوعية: Male, Larynx, medicine.medical_specialty, Voice Quality, Robotic assisted, Laryngectomy, Epiglottis, Cricoid Cartilage, Voice analysis, 03 medical and health sciences, 0302 clinical medicine, Robotic Surgical Procedures, Quality of life, medicine, Humans, 030223 otorhinolaryngology, Laryngeal Neoplasms, Partial laryngectomy, Aged, Performance status, business.industry, Head and neck cancer, Hyoid Bone, Maximum phonation time, Historically Controlled Study, Middle Aged, medicine.disease, Deglutition, medicine.anatomical_structure, Otorhinolaryngology, 030220 oncology & carcinogenesis, Carcinoma, Squamous Cell, Quality of Life, Physical therapy, Feasibility Studies, Female, business
الوصف: BACKGROUND We report on the feasibility and functional outcome of transoral robotic (TORS) supracricoid partial laryngectomy (SCPL) with cricohyoidoepiglottopexy (CHEP). METHODS Cadaveric studies and functional outcome at 3 years using the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC-QLQ-H&N35), the Functional Outcome Swallowing Scale (FOSS), the Performance Status Scale for Head and Neck Cancer (PSS-HN), computerized voice analysis, and videotape recordings. Data were compared with a historical cohort of open CHEPs/cricohyoidopexies (CHPs). RESULTS The EORTC-QLQ-H&N35 scores, FOSS scores, and PSS-HN scores at 3 years of 2 operated patients were 46 and 43, 2 and 1, and 75 of 100 (eating in public) and 100 of 100 (normalcy of diet), respectively. The mean fundamental frequency, jitter, shimmer, noise-to-harmonic ratio (NHR), and maximum phonation time (MPT) were 85 HZ and 81 Hz, 8.52% and 6.39%, 28.2% and 13.5%, 0.61 and 0.71, 19 seconds and 15 seconds, respectively. CONCLUSION Functional outcome data suggest that the procedure is feasible and safe.
تدمد: 1043-3074
DOI: 10.1002/hed.25332
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::1eb72f66061b15bb67d5ccb687ba0b7f
https://doi.org/10.1002/hed.25332
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....1eb72f66061b15bb67d5ccb687ba0b7f
قاعدة البيانات: OpenAIRE
الوصف
تدمد:10433074
DOI:10.1002/hed.25332