GAMMA DOSE RATE ANALYSIS IN BIOLOGICAL SHIELDING OF HTGR-10 MWth PEBBLE-BED REACTOR

التفاصيل البيبلوغرافية
العنوان: GAMMA DOSE RATE ANALYSIS IN BIOLOGICAL SHIELDING OF HTGR-10 MWth PEBBLE-BED REACTOR
المؤلفون: Entin Hartini, Ainon Hamzah, Hery Adrial
المصدر: Urania, Vol 25, Iss 1 (2019)
بيانات النشر: Pusat Teknologi Bahan Bakar Nuklir, 2019.
سنة النشر: 2019
مصطلحات موضوعية: Nuclear reaction, Materials science, Pebble-bed reactor, business.industry, lcsh:T, Nuclear engineering, Radiation, lcsh:Technology, lcsh:TK9001-9401, Shield, Electromagnetic shielding, lcsh:Nuclear engineering. Atomic power, Neutron, lcsh:Electrical engineering. Electronics. Nuclear engineering, Radiation protection, Pebble, business, lcsh:TK1-9971
الوصف: GAMMA DOSE RATE ANALYSIS IN BIOLOGICAL SHIELDING OF HTGR-10 MWth PEBBLE BED REACTOR. HTGR-10 MWth is a high-temperature gas-cooled reactor. The fuel and moderator are pebble shaped with a radius of 3 cm. One fuel pebble consists of thousands of UO2 kernels with a density of 10.4 gram/cc and the enrichment rate of 17%. The core of HTGR-10 MWth is the center of origin of neutrons and gamma radiation resulting from the interaction of neutrons with pebble fuel, moderator and biological shield. The various types of radiations generated from such nuclear reactions should be monitored to ensure the safety of radiation workers. This research was conducted using MCNP-6 Program package with the aim to calculate and analyze gamma radiation dose in biological shield of HTGR-10 MWth. In this study, the biological shield is divided into 10 equal segments. The first step of the research is to benchmark the created program against the critical height of HTR-10. The results of the benchmarking show an error rate of ± 1.1327%, while the critical core height of HTGR 10 MWth for the ratio of pebble fuel and pebble moderator (F:M) of 52: 48 occurs at a height of 134 cm. The rate of gamma dose at the core is 3.0052E + 05 mSv/hr. On the biological shield made of regular concrete with a density of 2.3 grams/cc, the rate of gamma dose decreases according to an equation y = 0.0042 e-0.03x. Referring to Perka Bapeten no 4 of 2013, the safe limits for workers and radiation protection officers will be achieved if the minimum thickness of biological shield is 115 cm with gamma dose rate of 0 mSv/hour.Keywords: Gamma dose rate, HTGR 10 MWth, biological shield, pebble
اللغة: English
تدمد: 2528-0473
0852-4777
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::150b9395d1ba24465f63c44ce8f85713
http://jurnal.batan.go.id/index.php/urania/article/view/4923
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....150b9395d1ba24465f63c44ce8f85713
قاعدة البيانات: OpenAIRE