Performance of the DELPHI small angle tile calorimeter

التفاصيل البيبلوغرافية
العنوان: Performance of the DELPHI small angle tile calorimeter
المؤلفون: Alvsvaag, S. J., Maeland, O. A., Klovning, A., Benvenuti, A. C., Giordano, V., Guerzoni, M., Navarria, F. L., Perrotta, A., Camporesi, T., Obraztsov, V., Paganoni, M., Vallazza, E., Bozzo, M., Cereseto, R., Barreira, G., Espirito Santo, M. C., Maio, A., Onofre, A., Peralta, L., Pimenta, M., Tome, B., Carling, H., Harris, Elisabeth Falk, Hedberg, V., Jarlskog, G., Kronkvist, I., Bonesini, M., Chignoli, F., Ferrari, P., Gumenyuk, S., Leoni, R., Mazza, R., Negri, P., Petrovykh, L., Terranova, F., Dharmasiri, D. R., Nossum, B., Read, Alexander L., Skaali, B., Rohne, O., Castellani, L., Pegoraro, M., Fenyuk, A., Ivanyushenkov, I., Karyukhin, A., Konoplyannikov, A., Shalanda, N., Senko, V., Vlasov, E., Zaitsev, A., Bigi, M., Cassio, V., Gamba, D., Gouz, I., Migliore, E., Romero, A., Simonetti, L., Trapani, P. P., Bari, M., Della Ricca, G., Livio Lanceri, Poropat, P., Prest, M.
المساهمون: K. J. Heller, J. K. Nelson, D. Reeder, DELLA RICCA, Giuseppe, Lanceri, Livio, Poropat, Paolo
المصدر: INSPIRE-HEP
سنة النشر: 1996
مصطلحات موضوعية: Nuclear and High Energy Physics, Optical fiber, Physics::Instrumentation and Detectors, law.invention, Sampling (signal processing), law, Nuclear electronics, Electronic engineering, luminosity, Electrical and Electronic Engineering, Image resolution, DELPHI, small angle tile calorimeter, shashlik, Physics, Detector, Particle accelerator, LARGE ELECTRON POSITRON COLLIDER, Calorimeter, Nuclear Energy and Engineering, PARTICLE PHYSICS, Large Electron–Positron Collider, High Energy Physics::Experiment, Particle Physics - Experiment
الوصف: The DELPHI STIC detector is a lead-scintillator sampling calorimeter with wavelength shifting optical fibers used for light collection. The main goal of the calorimeter at LEP100 is to measure the luminosity with an accuracy better than 0.1%. The detector has been in operation since the 1994 LEP run. Presented here is the performance measured during the 1994-1995 LEP runs, with the emphasis on the achieved energy and space resolution, the long-term stability and the efficiency of the detector. The new bunch-trains mode of LEP requires a rather sophisticated trigger and timing scheme which is also presented. To control the trigger efficiency and stability of the calorimeter channels, a LED-based monitoring system has been developed.
وصف الملف: STAMPA
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::14849cf0996a49a9a44bec7e6de78086
http://hdl.handle.net/11383/1791178
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....14849cf0996a49a9a44bec7e6de78086
قاعدة البيانات: OpenAIRE