Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries
العنوان: | Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries |
---|---|
المؤلفون: | Joern J.W. Sandstede, Anne Roth, Cornelia Harz, Dietbert Hahn, Manfred Jenett, Christine Kaupert |
المصدر: | European Radiology. 15:1211-1214 |
بيانات النشر: | Springer Science and Business Media LLC, 2005. |
سنة النشر: | 2005 |
مصطلحات موضوعية: | Male, medicine.medical_specialty, Iohexol, chemistry.chemical_element, Iodine, Statistics, Nonparametric, Renal Artery, medicine.artery, medicine, Humans, Radiology, Nuclear Medicine and imaging, Renal artery, Aged, Computed tomography angiography, medicine.diagnostic_test, business.industry, Ultrasound, Angiography, Iopromide, General Medicine, Contrast medium, chemistry, Injections, Intravenous, Female, Radiology, Tomography, X-Ray Computed, Nuclear medicine, business, medicine.drug |
الوصف: | The aims of this study were (1) to assess the diagnostic performance of multidetector row computed tomography angiography (CTA) on imaging of renal artery branches and (2) to investigate the effect of different iodine concentrations at constant total iodine load and either constant injection rates or constant iodine administration rates. A number of 120 consecutive patients (71+/-6 years of age) underwent CTA of renal arteries (collimation 4 x 1 mm) using the nonionic contrast medium iopromide, and were divided into six equal groups: 1: 150 ml, 240 mg/ml at 4 ml/s; 2: 120 ml, 300 mg/ml at 4 ml/s; 3: 97.3 ml, 370 mg/ml at 4 ml/s; 4: 150 ml, 240 mg/ml at 5 ml/s; 5: 120 ml, 300 mg/ml, 60 ml at 6 ml/s, 60 ml at 3 ml/s; 6: 97.3 ml, 370 mg/ml at 3.3 ml/s. The image quality of the main renal arteries (n=240) and their first-order to fourth-order branches was scored as 0 for no visualization, 1 for only visualization, and 2 for diagnostic. All main renal arteries were diagnostic. First-order branches had score 2 in 38/40, 40/40, 37/40, 38/40, 39/40, and 40/40 patients for groups 1-6, respectively (p=0.34). Second-order branches were imaged best in group 2 (p |
تدمد: | 1432-1084 0938-7994 |
DOI: | 10.1007/s00330-005-2677-1 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0f6a2c313f5952c944fecfa682dadb6d https://doi.org/10.1007/s00330-005-2677-1 |
Rights: | CLOSED |
رقم الانضمام: | edsair.doi.dedup.....0f6a2c313f5952c944fecfa682dadb6d |
قاعدة البيانات: | OpenAIRE |
تدمد: | 14321084 09387994 |
---|---|
DOI: | 10.1007/s00330-005-2677-1 |