On the combined use of laser-cut panel light redirecting systems and horizontal blinds for daylighting and solar heat control, a focus on visual comfort objectives

التفاصيل البيبلوغرافية
العنوان: On the combined use of laser-cut panel light redirecting systems and horizontal blinds for daylighting and solar heat control, a focus on visual comfort objectives
المؤلفون: Francesco Fiorito, Chantal Basurto Davila
المصدر: Solar Energy. 230:186-194
بيانات النشر: Elsevier BV, 2021.
سنة النشر: 2021
مصطلحات موضوعية: Focus (computing), Renewable Energy, Sustainability and the Environment, Computer science, Window (computing), Glare (vision), Laser-cut panel (LCP), Radiance, Useful daylight illuminance (UDI), Daylight glare probability (DGP), Solar control and daylight redirection, Visual comfort, Bidirectional scattering distribution function, General Materials Science, Daylight, Daylighting, Simulation, Efficient energy use
الوصف: Aiming to explore its performance as energy efficient system, in this study, the window is subdivided according to functions, in which the upper part would act as a daylight optimization unit. Two variant positions of lasercut panel, known as ‘louvre-style’ and ‘venetian-style’ are placed in the upper window unit, in order to take advantage of their angle selective redirecting capabilities. Their effectiveness to provide a satisfactory visual comfort is evaluated by assessing their potential for solar control and daylight redirection indoors. The first results indicate that the use of lasercut panel as a sole system, its insufficient to provide an adequate visual environment, with a reduced risk of glare for the occupants. Aiming to improve its performance, horizontal blinds are added as supplementary element to the interior-upper part of the window, blended in an arrangement called ‘secondary system’. As a result of a comprehensive evaluation, in which, the upper and middle window units are considered, two lasercut panel styles are identified as those providing sufficient daylight provision indoors, and a reduced risk of discomfort glare. The properties of the fenestration systems tested here, were described using their corresponding BSDF data, while the evaluation was performed using the RADIANCE matrix multiplication methods.
تدمد: 0038-092X
DOI: 10.1016/j.solener.2021.09.071
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0b801890394ced327b8619d1944e43be
https://doi.org/10.1016/j.solener.2021.09.071
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....0b801890394ced327b8619d1944e43be
قاعدة البيانات: OpenAIRE
الوصف
تدمد:0038092X
DOI:10.1016/j.solener.2021.09.071