Doubly labelled water for determining total energy expenditure in adult critically ill and acute care hospitalized inpatients: A scoping review

التفاصيل البيبلوغرافية
العنوان: Doubly labelled water for determining total energy expenditure in adult critically ill and acute care hospitalized inpatients: A scoping review
المؤلفون: Oana A. Tatucu-Babet, Kay Nguo, Kate J. Lambell, Lorena Romero, Carrie P. Earthman, Emma J. Ridley
المصدر: Clinical Nutrition. 41:424-432
بيانات النشر: Elsevier BV, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Adult, Aged, 80 and over, Male, Inpatients, Parenteral Nutrition, Nutrition and Dietetics, Staining and Labeling, Critical Illness, Calorimetry, Indirect, Middle Aged, Critical Care and Intensive Care Medicine, Intensive Care Units, Nutrition Assessment, Body Water, Isotopes, Fluid Therapy, Humans, Female, Energy Metabolism, Aged
الوصف: Doubly labelled water (DLW) is considered the reference standard method of measuring total energy expenditure (TEE), but there is limited information on its use in the Intensive Care Unit (ICU) and acute care setting. This scoping review aims to systematically summarize the available literature on TEE measured using DLW in these contexts.Four online databases (MEDLINE, Embase, Emcare and CINAHL) were searched up to Dec 12, 2020. Studies in English were included if they measured TEE using DLW in adults in the ICU and/or acute care setting. Key considerations, concerns and practical recommendations were identified and qualitatively synthesized.The search retrieved 7582 studies and nine studies were included; one in the ICU and eight in the acute care setting. TEE was measured over 7-15-days, in predominantly clinically stable patients. DLW measurements were not commenced until four days post admission or surgery in one study and following a 10-14-day stabilization period on parenteral nutrition (PN) in three studies. Variable dosages of isotopes were administered, and several equations used to calculate TEE. Four main considerations were identified with the use of DLW in these settings: variation in background isotopic abundance; excess isotopes leaving body water as carbon dioxide or water; fluctuations in rates of isotope elimination and costs.A stabilization period on intravenous fluid and PN regimens is recommended prior to DLW measurement. The DLW technique can be utilized in medically stable ICU and acute care patients, with careful considerations given to protocol design.
تدمد: 0261-5614
DOI: 10.1016/j.clnu.2021.12.017
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0794a8d97785fe5a9ef62885e7fb1b86
https://doi.org/10.1016/j.clnu.2021.12.017
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....0794a8d97785fe5a9ef62885e7fb1b86
قاعدة البيانات: OpenAIRE
الوصف
تدمد:02615614
DOI:10.1016/j.clnu.2021.12.017