Kinetic determination of gold (III) based on its inhibitory effect in oxidizing homogenous reaction system
العنوان: | Kinetic determination of gold (III) based on its inhibitory effect in oxidizing homogenous reaction system |
---|---|
المؤلفون: | Ruzica Micic, Ranko M. Simonovic, Snezana S. Mitic, Dragana Sejmanovic |
المصدر: | The University Thought: Publication in Natural Sciences, Vol 6, Iss 2, Pp 11-16 (2016) |
بيانات النشر: | University of Priština - Faculty of Natural Science and Mathematics, Kosovska Mitrovica, 2016. |
سنة النشر: | 2016 |
مصطلحات موضوعية: | Chemistry, gold(III), Analytical chemistry, Kinetic energy, sunset yellow, Redox, Ion, chemistry.chemical_compound, Gold iii, Reagent, Sunset Yellow FCF, Oxidizing agent, lcsh:Q, lcsh:Science, Inhibitory effect, kinetic method |
الوصف: | Development and application of a simple, fast, green analytical kinetic method for the determination of micro-amounts of gold(III ) ions, were presented in this paper. The method was based on the inhibitory effect of traces of Au(III) ions on the redox reaction between disodium- 6 -hydroxy- 5 -[( 4 -sulfophenyl)azo]- 2 -naphtalenesulfonate (artificial azo-dye "Sunset Yellow FCF", E110 in further text selected as SY ) and hydrogen-peroxide, in alkaline media of borate buffer. All experimental parameters affecting to the determination: reagent concentrations, pH and temperature were in v estigated and optimised. Working experimental conditions are set according to the highest sensitivity of the proposed kinetic method for the determination of Au(III) ions. The linearity of the method was obtained within the range 1.97-59.07 μg/mL of Au(III) ions with relative standard deviation of 3.66- 0.43 %, respectively. The influence by possible interference effects by major ions on the determination of Au(III) and their limits are investigated, at the constant Au(III) concentration of 39.39 μg/mL. The results of Au(III) determination in samples obtained by proposed kinetic method and comparative ICP-OES method were statistically agreeable. Obtained results for Au(III) determination in analyzed samples, as well as the development and validation of the proposed analytical procedure have given and discussed. |
اللغة: | English |
تدمد: | 2560-3094 1450-7226 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0295eff8c58caee8f706106693550e6a http://scindeks-clanci.ceon.rs/data/pdf/1450-7226/2016/1450-72261602011M.pdf |
Rights: | OPEN |
رقم الانضمام: | edsair.doi.dedup.....0295eff8c58caee8f706106693550e6a |
قاعدة البيانات: | OpenAIRE |
تدمد: | 25603094 14507226 |
---|