Initial Experience with the E-liac® Iliac Branch Device for the Endovascular Aortic Repair of Aorto-iliac Aneurysm

التفاصيل البيبلوغرافية
العنوان: Initial Experience with the E-liac® Iliac Branch Device for the Endovascular Aortic Repair of Aorto-iliac Aneurysm
المؤلفون: Erik Stahlberg, F Jacob, Jörg Barkhausen, Marcus Wiedner, Susanne Anton, Jan Peter Goltz
المصدر: CardioVascular and Interventional Radiology.
بيانات النشر: Springer Science and Business Media LLC, 2018.
سنة النشر: 2018
مصطلحات موضوعية: medicine.medical_specialty, business.industry, medicine.medical_treatment, 030204 cardiovascular system & hematology, Revascularization, Common iliac artery, Internal iliac artery, Surgery, 03 medical and health sciences, 0302 clinical medicine, medicine.artery, Superior gluteal artery, Occlusion, medicine, Radiology, Nuclear Medicine and imaging, 030212 general & internal medicine, Iliac Aneurysm, Embolization, Endovascular treatment, Cardiology and Cardiovascular Medicine, business
الوصف: Occlusion of internal iliac arteries during endovascular treatment (EVAR) of abdominal aortic (AAA) and common iliac artery aneurysms might be associated with ischemic pelvic complications. This study evaluates technical and clinical success, safety and mid-term results of a novel iliac branch device (IBD) for revascularization of the internal iliac artery (IIA) during EVAR. Retrospectively, we identified 21 men (mean age 73.3 ± 6.2 years) treated for aorto-iliac aneurysms by use of a novel IBD (E-liac®, Jotec Hechingen, Germany). We analyzed safety (30-day survival), technical (no type I and III endoleaks, “EL”), clinical (no ischemic complications) success, mid-term patency of this IBD, peri-procedural complications, occurrence of type II ELs, rate of re-interventions and additional treatment of the revascularized IIA for landing zone preparation. Twenty-three IBDs were implanted. Aneurysms of the ipsilateral IIA were present in 6/23 IIAs (26.1%). Super-selective branch embolization was performed in these patients and the landing zone for the iliac sidebranch stent-graft was within the superior gluteal artery. Mean follow-up was 341 days (range 4–1103 days). Technical success and 30-day survival were 100%. Clinical success was 95.2%. Primary patency of the IBDs was 100% at 12 months. Peri-procedural complications occurred in 3/21 patients (14.3%), none of them related to the IBD. AAA-related type II ELs were found in 6 patients (28.6%), IBD-related ELs in 4/23 IBDs (17.4%) (two type Ib, two type II endoleaks). Overall re-intervention rate was 23.8%, IBD-related 8.7%. Utilization of the E-liac® IBD is safe and effective for the treatment of aorto-iliac aneurysms.
تدمد: 1432-086X
0174-1551
DOI: 10.1007/s00270-017-1868-x
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::df86cac691755aeb2aa9ef7bd2d224cd
https://doi.org/10.1007/s00270-017-1868-x
Rights: CLOSED
رقم الانضمام: edsair.doi...........df86cac691755aeb2aa9ef7bd2d224cd
قاعدة البيانات: OpenAIRE
الوصف
تدمد:1432086X
01741551
DOI:10.1007/s00270-017-1868-x