Effect of the refrigerant charge, expansion restriction, and compressor speed interactions on the energy performance of household refrigerators

التفاصيل البيبلوغرافية
العنوان: Effect of the refrigerant charge, expansion restriction, and compressor speed interactions on the energy performance of household refrigerators
المؤلفون: Adriano F. Ronzoni, Christian J.L. Hermes, Fernando T. Knabben
المصدر: International Journal of Refrigeration. 130:347-355
بيانات النشر: Elsevier BV, 2021.
سنة النشر: 2021
مصطلحات موضوعية: Range (particle radiation), Work (thermodynamics), Materials science, Capillary action, 020209 energy, Mechanical Engineering, Refrigerator car, 02 engineering and technology, Building and Construction, Mechanics, Energy consumption, 021001 nanoscience & nanotechnology, Refrigerant, 0202 electrical engineering, electronic engineering, information engineering, Hydraulic diameter, 0210 nano-technology, Gas compressor
الوصف: This work is aimed at investigating the effects of the refrigerant charge, expansion device restriction, compressor speed, and their interactions on the performance of a household refrigerator. To this end, a micrometric valve was installed in series with the capillary tube of a frost-free refrigerator to vary the expansion restriction within a range equivalent to capillary tubes with inner diameters spanning from 0.55 to 0.85 mm. The refrigerant charge was manually changed from 35 to 65 g whereas the compressor speed was adjusted between 2500 and 4500 rpm. In total, 294 steady-state energy consumption tests were conducted, being 147 at a surrounding temperature of 32 °C, and the rest at 16 °C. It was noticed that low energy consumptions can be achieved for several combination of refrigerant charge and expansion restriction, albeit the minimal energy consumption figures were always achieved for the highest charges and restrictions. It was also verified that the refrigerator operates in a sub-optimum region so that increasing the charge from 42 g to 52 g while decreasing the capillary tube diameter from 0.64 mm to 0.60 mm led to a 3% decrease on the energy consumption. It was also found that a single combination of refrigerant charge and equivalent diameter provided satisfactory performance levels regardless of the compressor speed. Finally, a method to reduce the number of tests was proposed, in such a way that only 9 datapoints are required to generate a full energy consumption map for a given compressor speed and surrounding temperature.
تدمد: 0140-7007
DOI: 10.1016/j.ijrefrig.2021.06.006
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::ae0333ad0bc7b880566c5bad37d417e8
https://doi.org/10.1016/j.ijrefrig.2021.06.006
Rights: CLOSED
رقم الانضمام: edsair.doi...........ae0333ad0bc7b880566c5bad37d417e8
قاعدة البيانات: OpenAIRE
الوصف
تدمد:01407007
DOI:10.1016/j.ijrefrig.2021.06.006