One Case of Suspected Angiostenosis Revealed by MRA Following Carotid Endarterectomy Due to a Rare Cause
العنوان: | One Case of Suspected Angiostenosis Revealed by MRA Following Carotid Endarterectomy Due to a Rare Cause |
---|---|
المؤلفون: | Toshihito Ishikawa, Kenichi Ebihara, Naoki Sato, Hidekazu Takahashi, Mamoru Ota, Yuji Endo, Katsuhiro Endo |
المصدر: | Open Journal of Modern Neurosurgery. :276-281 |
بيانات النشر: | Scientific Research Publishing, Inc., 2018. |
سنة النشر: | 2018 |
مصطلحات موضوعية: | medicine.medical_specialty, medicine.diagnostic_test, business.industry, medicine.medical_treatment, Carotid ultrasonography, Carotid endarterectomy, medicine.disease, Magnetic resonance angiography, Stenosis, medicine.artery, Angiography, medicine, Surgical instrument, Common carotid artery, Radiology, Internal carotid artery, business |
الوصف: | We herein report on a case in which magnetic resonance angiography (MRA) following carotid endarterectomy revealed the appearance of angiostenosis due to an artifact of metallic powder, which was thought to have come from an old surgical instrument. The patient was a 77-year-old male. Carotid endarterectomy (CEA) was performed for stenosis in the internal carotid artery of his left neck (82%). Upon observing a decline in renal function following CEA surgery, a postoperative cervical MRA revealed the appearance of high-grade stenosis at the common carotid artery on which surgery was performed. No stenosis was revealed upon carotid ultrasonography and angiography. In the original MRA image, an orbicular low intensity area was observed in concordance with the narrow segment. 3D computed tomography (3D-CT) revealed a metallic finding, suggesting it was an artifact caused by metal powder. Close inspection of the metal surgical instruments used during surgery revealed slight damage to a suture snare which had been used for 30 years. Going forward, it is necessary to pay attention to old surgical instruments, introduce a system by which the number of years and the frequency of use of each surgical instrument can be learned, and replace them with new equipment as necessary. |
تدمد: | 2163-0585 2163-0569 |
DOI: | 10.4236/ojmn.2018.83023 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_________::81176cbd8d104b56dc3692b0fda108a7 https://doi.org/10.4236/ojmn.2018.83023 |
Rights: | OPEN |
رقم الانضمام: | edsair.doi...........81176cbd8d104b56dc3692b0fda108a7 |
قاعدة البيانات: | OpenAIRE |
تدمد: | 21630585 21630569 |
---|---|
DOI: | 10.4236/ojmn.2018.83023 |